scholarly journals Semiautomated quantification of the fibrous tissue response to complex three‐dimensional filamentous scaffolds using digital image analysis

Author(s):  
Friedrich Barsch ◽  
Andreas Mamilos ◽  
Maximilian Babel ◽  
Willi L. Wagner ◽  
Hinrich B. Winther ◽  
...  
2003 ◽  
Vol 12 (2) ◽  
pp. 129-133 ◽  
Author(s):  
Peter Girman ◽  
Jan Kříž ◽  
Jozef Friedmanský ◽  
FrantišEk Saudek

Digital image analysis (DIA) is a new method in assessment of islet amount, which is expected to provide reliable and consistent results. We compared this method with conventional counting of small numbers of rat islets. Islets were isolated from 8 pancreases and counted in 24 samples in duplicate, first routinely by sizing according to estimated diameters under a calibrated reticule and then by processing of islets pictures taken by camera. As presumed, no significant difference was found in absolute numbers of islets per sample between DIA and conventional assessment. Volumes of islets per sample measured by DIA were on average more than 10% higher than amounts evaluated conventionally, which was statistically significant. DIA has been shown to be an important method to remove operator bias and provide consistent results. Evaluation of only two dimensions of three-dimensional objects still represents a certain limitation of this technique. With lowering of computer prices the system could become easily available for islet laboratories.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2439
Author(s):  
Teemu Ojala ◽  
Yanjuan Chen ◽  
Jouni Punkki ◽  
Fahim Al-Neshawy

This paper presents the characteristics of air void systems in hardened concrete with the method of digital image analysis (DIA) coupled with Schwartz-Saltykov (SS) conversion. The results indicate that the DIA method coupled with SS conversion estimates the air content with more accuracy than it would without SS conversion; the correlation between air content obtained from the DIA method, and that from the thin section (TS) method is as good as the correlation observed between the pressure saturation (PS) method and the TS method. It was also found that the DIA method shows a better correlation with the TS method when the spacing factor without SS conversion is considered, while both methods show poor correlations when the corresponding specific surface is considered. In addition, it indicates that the peak of three-dimensional size distribution (3-DSD) of air voids after SS conversion falls in smaller voids, and 3-DSD of air voids shifts to a narrow size range, in comparison with the 2-DSD without SS conversion; the shape of the 3-DSD air voids remains constant irrespective of the class widths. Increasing the number of classes can minimise the standard deviation in the estimation, however, it also results in a leap in voids volume density, which will influence the estimation of air content.


2006 ◽  
Vol 12 (5) ◽  
pp. 366-375 ◽  
Author(s):  
Roland Zippel ◽  
Andreas Hoene ◽  
Uwe Walschus ◽  
Raymond Jarchow ◽  
Torsten Ueberrueck ◽  
...  

The aim of this study was to examine the suitability of digital image analysis, using the KS400 software system, for the morphometric evaluation of the tissue response after prosthesis implantation in an animal model. Twenty-four female pigs aged 10 weeks were implanted with infrarenal Dacron® prostheses for 14, 21, 28, and 116 days. Following the explantation and investigation of the neointima region, the expression of beta-1-integrin, the proliferation rate by means of Ki-67 positive cells, and the intima thickness were evaluated as exemplary parameters of the tissue response after implantation. Frozen tissue sections were immunohistochemically stained and subsequently examined using computer-aided image analysis. A maximum expression of 32.9% was observed for beta-1-integrin 14 days after implantation, gradually declining over time to 9.8% after 116 days. The proliferation rate was found to be 19% on day 14, increasing to 39% on day 21 with a subsequent gradual decline to 5% after 116 days. The intima thickness increased from 189.9 μm on day 14 to 1228.0 μm on day 116. In conclusion, digital image analysis was found to be an efficient and reproducible method for the morphometric evaluation of a peri-prosthetic tissue response.


2000 ◽  
Vol 10 (2) ◽  
pp. 7-9
Author(s):  
Yaser Natour ◽  
Christine Sapienza ◽  
Mark Schmalz ◽  
Savita Collins

Sign in / Sign up

Export Citation Format

Share Document