Inverse spatially‐offset Raman spectroscopy using optical fibers: An axicon lens‐free approach

2019 ◽  
Vol 12 (11) ◽  
Author(s):  
Khan Mohd. Khan ◽  
Surjendu B. Dutta ◽  
Nitin Kumar ◽  
Anita Dalal ◽  
Amrita Srivastava ◽  
...  
1981 ◽  
Vol 35 (4) ◽  
pp. 439-442 ◽  
Author(s):  
Howard B. Ross ◽  
William M. McClain

Raman spectra of samples contained in hollow quartz fibers are compared quantitatively to conventional Raman spectra using identical laser, spectrometer, detector, and scan speed. We find the fiber signal to be enhanced by a factor of 250/m of fiber, in good agreement with calculations based on geometrical optics. A fiber spectrum of 2 mol% trans-stilbene in benzene is good enough to allow essentially perfect solvent subtraction.


Sensors ◽  
2013 ◽  
Vol 13 (10) ◽  
pp. 13163-13177 ◽  
Author(s):  
Georgios Tsiminis ◽  
Fenghong Chu ◽  
Stephen Warren-Smith ◽  
Nigel Spooner ◽  
Tanya Monro

1975 ◽  
Vol 29 (4) ◽  
pp. 337-344 ◽  
Author(s):  
G. E. Walrafen ◽  
J. Stone

The utility of Raman spectroscopy as a means of characterizing the properties of pure and doped fused silica has been investigated. Laser-Raman spectra were obtained by forward scattering from solid optical fibers ∼35 to 85 m in length using 514.5 nm excitation with an “image slicer” and a Cary model 81 instrument. Clad and unclad fibers of fused silica and doped fibers having SiO2-GeO2 and SiO2-GeO2-B2O3 cores were examined. Raman spectra were also obtained from bulk samples of glasses, including pure GeO2, pure B2O3, and various compositions of SiO2-GeO2, SiO2-B2O3, and SiO2-GeO2-B2O3. The addition of dopants to fused silica was found to alter the Raman spectrum both by the appearance of new bands, roughly proportional to dopant concentration and not common either to the fused silica or to the dopant alone, and by the marked alteration of other Raman bands, which is indicative of changes in the local intermolecular order. Thus, addition of GeO2 produces new Raman bands at ∼675 and ∼1000 cm−1; and of B2O3, new bands at ∼940 and ∼1350 cm−1. Addition of GeO2 and/or B2O3 weakens the relatively sharp Raman lines near 485 and 600 cm−1 (and a similar but small effect was also noted with increasing OH content). GeO2 and B2O3 together also produce observable narrowing of the broad intense 440 cm−1 Raman contour. These spectral effects are interpreted, respectively, in terms of a decrease in the concentrations of [Formula: see text] and [Formula: see text] defects produced by dopant addition and of a concomitant reordering of the silica structure. Raman spectroscopy thus appears to be a useful optical technique for elucidating the properties of dopants that have been especially chosen for good optical transmission and hence are not easily detectable by absorption measurements.


1988 ◽  
Vol 42 (8) ◽  
pp. 1558-1563 ◽  
Author(s):  
D. D. Archibald ◽  
L. T. Lin ◽  
D. E. Honigs

A commercial Fourier transform infrared (FT-IR) spectrometer was modified for remote near-IR Raman spectroscopy. In one configuration, a single optical fiber was used to guide the excitation light to the specimen and to collect scattered light from the specimen. In an alternative configuration, separate fibers were used for excitation and collection. The optical fiber probes were used to record the Raman spectra of both liquid and solid specimens. The Raman scattering of the optical fibers interfered with the analyte signal. This fiber interference was affected by the optical properties of the specimen and the optical sampling configuration. These interferences were partially removed by subtracting a background spectrum. Potential applications and improvements are discussed.


Author(s):  
B. J. McKinley ◽  
Sang Sheem ◽  
John Lutz ◽  
Fred P. Milanovich

The recent availability of moderate power near-infrared diode lasers (780nm) and near-infrared sensitive ccd detectors have caused a noticeable resurgence in the application of Raman spectroscopy in analytical chemistry. We have long maintained an interest in Raman spectroscopy and have established a micro-Raman facility within the Chemistry Department of our organization. Recently, we have taken advantage of the aforementioned progress in spectroscopic equipment and have upgraded our micro-Raman facility to include a ccd detector and an imaging spectrograph.Since our micro-Raman spectrometer is designed around an ellipsoidal collection mirror, with Raman signal being directed through the illumination sample stage it has application to microscopic or small transparent samples. The improved performance of the device and the availability of highly transmissive optical fibers led one of us (B.J.M.) to propose an apparatus that could replace the existing illuminator with a miniature device that maintains a high collection efficiency and can be used remotely or in-situ by utilizing optical fibers.


2006 ◽  
Vol 11-12 ◽  
pp. 209-212 ◽  
Author(s):  
N. Iwafuchi ◽  
S. Mizuno ◽  
Yasuhiko Benino ◽  
Takumi Fujiwara ◽  
Takayuki Komatsu ◽  
...  

Transparent nano-crystallized glass fibers with 300μm diameter were successfully fabricated in tellurite (TeO2) based glass systems. Structure of crystallized glass fibers and orientation of nano-size crystals were quantitatively investigated by microscopic Raman spectroscopy and X-ray diffraction. Second harmonic generation was measured in the nano-crystallized optical fibers.