Ultrasonic determination of gestational age by assessment of fetal kidney size in the third trimester in southwest Nigeria

2019 ◽  
Vol 144 (3) ◽  
pp. 271-276
Author(s):  
Evelyn S. Osho ◽  
Bolanle O. Ibitoye ◽  
Victor A. Adetiloye ◽  
Adebanjo B. Adeyemi ◽  
Adeniyi S. Aderibigbe ◽  
...  
Author(s):  
E.A. Derkach , O.I. Guseva

Objectives: to compare the accuracy of equations F.P. Hadlock and computer programs by V.N. Demidov in determining gestational age and fetal weight in the third trimester of gestation. Materials: 328 patients in terms 36–42 weeks of gestation are examined. Ultrasonography was performed in 0–5 days prior to childbirth. Results: it is established that the average mistake in determination of term of pregnancy when using the equation of F.P. Hadlock made 12,5 days, the computer program of V.N. Demidov – 4,4 days (distinction 2,8 times). The mistake within 4 days, when using the equation of F.P. Hadlock has met on average in 23,1 % of observations, the computer program of V.N. Demidov — 65,9 % (difference in 2,9 times). The mistake more than 10 days, took place respectively in 51,7 and 8,2 % (distinction by 6,3 times). At a comparative assessment of size of a mistake in determination of fetal mass it is established that when using the equation of F.P. Hadlock it has averaged 281,0 g, at application of the computer program of V.N. Demidov — 182,5 g (distinction of 54 %). The small mistake in the mass of a fetus which isn't exceeding 200 g at application of the equation of F.P. Hadlock has met in 48,1 % of cases and the computer program of V.N. Demidov — 64,0 % (distinction of 33,1 %). The mistake exceeding 500 g has been stated in 18 % (F.P. Hadlock) and 4,3 % (V.N. Demidov) respectively (distinction 4,2 times). Conclusions: the computer program of V.N. Demidov has high precision in determination of term of a gestation and mass of a fetus in the III pregnancy.


2021 ◽  
Vol 11 (03) ◽  
pp. 221-232
Author(s):  
Mahmoud Mohamed Ghaleb ◽  
Afnan Ibrahim Abdel Fatah Shokri ◽  
Mohammed Salah El Sayed El Sokkary ◽  
Maged Mahmoud Ali El Shourbagy

Rheumatology ◽  
2021 ◽  
Author(s):  
Rugina I Neuman ◽  
Hieronymus T W Smeele ◽  
A H Jan Danser ◽  
Radboud J E M Dolhain ◽  
Willy Visser

Abstract Objectives An elevated sFlt-1/PlGF-ratio has been validated as a significant predictor of preeclampsia, but has not been established in women with rheumatoid arthritis (RA). We explored whether the sFlt-1/PlGF-ratio could be altered due to disease activity in RA, and could be applied in this population to predict preeclampsia. Since sulfasalazine has been suggested to improve the angiogenic imbalance in preeclampsia, we also aimed to examine whether sulfasalazine could affect sFlt-1 or PlGF levels. Methods Making use of a nationwide, observational, prospective cohort study on pregnant women with RA, sFlt-1 and PlGF were measured in the third trimester. A total of 221 women, aged 21–42 years, were included, with a median gestational age of 30 + 3 weeks. Results No differences in sFlt-1 or PlGF were observed between women with high, intermediate or low disease activity (p= 0.07 and p= 0.41), whereas sFlt-1 and PlGF did not correlate with DAS28-CRP score (r=-0.01 and r=-0.05, respectively). Four (2%) women with a sFlt-1/PlGF-ratio ≤38 developed preeclampsia in comparison to three (43%) women with a ratio > 38, corresponding to a negative predictive value of 98.1%. Sulfasalazine users (n = 57) did not show altered levels of sFlt-1 or PlGF in comparison to non-sulfasalazine users (n = 164, p= 0.91 and p= 0.11). Conclusion Our study shows that in pregnant women with RA, the sFlt-1/PlGF-ratio is not altered due to disease activity and a cut-off ≤38 can be used to exclude preeclampsia. Additionally, sulfasalazine use did not affect sFlt-1 or PlGF levels in this population.


2021 ◽  
pp. 64-66
Author(s):  
Sambhunath Bandyopadhyay ◽  
Ritayan Sasmal ◽  
Debarshi Jana

Accurate gestational age determination is very important for management of continuation and termination planning of the pregnancy. rd To establish placental thickness as a parameter for determination of gestational age and fetal growth pattern at 3 trimester. 100 primigravida women who are fullling the inclusion criteria and attend gynae &obs OPD or admitted in their third trimester at IPGME&R from January 2017 to june 2018. Placental thickness at 3rd trimester USG scan is moderately correlated with gestational age, if placental thickness expressed in millimeter then it correlated with gestational age at weeks. rd st Placental thickness with >3.2 cm (32 mm) at 3 trimester almost associated with good fetal outcome, with APGAR score >8 at 1 min and birth weight >2500 gm.


2018 ◽  
Vol 5 (3) ◽  
pp. 142
Author(s):  
Moawia Gameraddin ◽  
Mohamed Ebraheem ◽  
BushraAbdel Malik ◽  
QurashiM Ali ◽  
Awadia Gareeballah

Sign in / Sign up

Export Citation Format

Share Document