Heat release rate and computer fire modellingvs real-scale fire tests in passenger trains

2008 ◽  
Vol 32 (4) ◽  
pp. 213-229 ◽  
Author(s):  
Jorge A. Capote ◽  
Daniel Alvear ◽  
Mariano Lázaro ◽  
Pablo Espina
1984 ◽  
Vol 2 (5) ◽  
pp. 380-395 ◽  
Author(s):  
W.J. Parker

The calculation of heat release rate by oxygen consumption is based on the assumption that all materials release approximately the same amount of heat per unit mass of oxygen consumed. This technique is now being employed to determine the heat release rate of materials in various heat release rate cal orimeters. Other uses include the heat release rate of assemblies in the fire en durance furnaces and the total heat release rate in room fire tests. These dif ferent applications lead to different experimental procedures which require dif ferent formulas. The experimental choices or constraints include open or closed systems, paramagnetic or high temperature oxygen analyzers, CO2 analyzers or CO2 traps, and the use of a gas burner whose heat release rate must be deducted from the total. Various assumptions about CO levels in the exhaust duct and vitiation and humidity in the incoming air are made. General formulas for the heat release rate by oxygen consumption are developed in this paper from which the formulas for specific applications can easily be derived.


2021 ◽  
Vol 21 (4) ◽  
pp. 49-59
Author(s):  
Oh Sang Kweon ◽  
Hyun Kang ◽  
Heung-Youl Kim

During an accidental fire in buildings, the corridor becomes the path for flame and smoke to spread, exposing the occupants to danger. Therefore, this study conducted real-scale fire experiments using corridors of size 2.4(L) × 10(W) × 2.4(H) m an “L-type” corridor for one-way evacuation and a “T-type” corridor for two-way evacuation to analyze the characteristics of fire according to the shape of corridors. The real-scale fire experiments were conducted in a fire room (2.4(L) × 3.6(W) × 2.4(H) m) with a single opening (2.0(W) × 1.8(H) m). The combustibles used inside the fire room were wood cribs, with a heat release rate of 651.4 kW, in the L-type corridor and chairs, with a heat release rate of 95.7 kW, in the T-type corridor. The temperature inside the corridor was measured during the real-scale fire experiments, and the average maximum measured temperature was 432.1 °C in the L-type corridor and 103.5 °C in the T-type corridor. The experimental results and the ventilation characteristics according to the corridor types were applied to BFD curves to show the process of designing fire growth models according to corridor types.


2010 ◽  
Vol 16 (4) ◽  
pp. 484-490 ◽  
Author(s):  
Romualdas Mačiulaitis ◽  
Vladas Praniauskas

The paper analyses three different wood products used for research exposing them to the surface heat flow density of 30 kW/m2, 50 kW/m2 and 70 kW/m2 and applying the test method described in ISO 5660–1 Reaction‐to‐fire tests – Heat release, smoke production and mass loss rate – Part 1: Heat release rate (Cone calorimeter method). Research was performed applying 18 mm and 29 mm thick laminated wood chipboards and 24 mm thick medium density fibreboard. The paper provides an overview of the fire properties of wood products and discusses testing methods and the percentage composition of the tested wood products. Mean time to their ignition was determined. The mean values of the maximum heat release rate and time required to achieve them were investigated. Furthermore, the measurements of the released heat and efficient heat of combustion were taken. Further research covers the performance of statistic analysis, deriving empiric equations, correlation and determination coefficients, standard errors and Student criterion. The results of research are summarized. Conclusions are provided at the end of the paper. Santrauka Straipsnyje nagrinejami trys skirtingi medienos gaminiai, su kuriais atlikti tyrimai veikiant 30 kW/m2, 50 kW/m2bei 70 kW/m2 paviršiniais šilumos srautais taikant ISO 5660–1 “Reaction‐to‐fire tests – Heat release, smoke production and mass loss rate – Part 1: Heat release rate (Cone calorimeter method)” bandymo metoda. Tyrimai atlikti su 18 mm ir 29 mm storio laminuotomis medžio drožliu plokštemis bei 24 mm storio vidutinio tankio plaušo plokšte. Darbe apžvel‐giamos medienos gaminiu gaisrines savybes. Aptariama bandymo metodika ir tirtu medienos gaminiu procentine sudetis. Nustatytas vidutinis laikas iki ju užsidegimo. Ištirti vidutiniai maksimalios šilumos išsiskyrimo greičio ir laiko iki ju pasiekimo dydžiai, taip pat išmatuota visa išskirta šiluma ir efektyvi degimo šiluma. Atlikta statistine analize, gautos em‐pirines lygtys, koreliacijos bei determinacijos koeficientai, standartines paklaidos bei Stjudento kriterijai. Apibendrinami tyrimo rezultatai. Darbo pabaigoje suformuluojamos išvados.


2008 ◽  
Vol 18 (2) ◽  
pp. 111-124 ◽  
Author(s):  
C. Chen ◽  
L. Qu ◽  
Y. X. Yang ◽  
G. Q. Kang ◽  
W. K. Chow

Sign in / Sign up

Export Citation Format

Share Document