Comparative study of air heating solar collectors

1991 ◽  
Vol 15 (6) ◽  
pp. 469-471 ◽  
Author(s):  
J. Naga Raju
2020 ◽  
Vol 224 ◽  
pp. 110265
Author(s):  
Rui Fan ◽  
Yue Li ◽  
Ting Bu ◽  
Kexin Sun ◽  
Yibing Zhou ◽  
...  

Author(s):  
Edward K. Summers ◽  
John H. Lienhard ◽  
Syed M. Zubair

Relative to solar water heaters, solar air heaters have received relatively little investigation and have resulted in few commercial products. However, in the context of a Humidification-Dehumidification (HDH) Desalination cycle, air heating accounts for advantages in cycle performance. Solar collectors can be over 40% of an air-heated HDH system’s cost, thus design optimization is crucial. Best design practices and sensitivity to material properties for solar air heaters are investigated, and absorber solar absorptivity and glazing transmissivity are found to have the strongest effect on performance. Wind speed is also found to have an impact on performance. Additionally a well designed, and likely low cost, collector includes a double glazing and roughened absorber plates for superior heat transfer to the airstream. A collector in this configuration performs better than current collectors with an efficiency of 58% at a normalized gain of 0.06 K m2/W.


1981 ◽  
Vol 103 (4) ◽  
pp. 323-330 ◽  
Author(s):  
K. G. T. Hollands ◽  
E. C. Shewen

The effect of the choice of shape and dimensions of the air flow passages in plate-type, air-heating solar collectors is assessed. Particularly examined is their effect on the overall heat transfer coefficient Upf between the air stream and the plate, which has an important effect on collector efficiency. It is emphasized in this study that in comparing various designs of flow passage, they should be compared for the same pressure drop Δp suffered by the air in passing through the collector, and for the same mass flow rate m per unit of collector area. On the basis of this type of comparison, two main conclusions are drawn. First, when the length of the air flow passage L is made less than about 1 m, Upf increases dramatically with decreasing values of L. Second, outside the transition regime, the value of Upf for a V-corrugated absorber plate is from 47 to 300 percent higher than that for a flat absorber plate, depending on whether the flow is laminar or turbulent, and on whether the V-corrugated plate is thermally bonded to the back plate. The first conclusion has led to a proposal for a novel air-heating solar collector design, called the “short-path” design.


2019 ◽  
Author(s):  
El Ghali Bennouna ◽  
Nour Eddine Laadel ◽  
Nawar Amahri ◽  
Ammar Mouaky

Sign in / Sign up