Analysis of the top heat loss factor of flat plate solar collectors with single and double glazing

1990 ◽  
Vol 14 (9) ◽  
pp. 975-990 ◽  
Author(s):  
S. K. Samdarshi ◽  
S. C. Mullick
1988 ◽  
Vol 41 (4) ◽  
pp. 623
Author(s):  
MJ O'Keefe ◽  
JLA Francey

An experimental study of flat-plate solar collectors using ethylene, propylenediene monomer (EPDM) absorber plates is descn"bed. In spite of the high thermal resistance of this material the performance is found to compare well with metal absorbers and to be in agreement with the Hottel-Whillier-Bliss equation. There is, however, an observed increase in the heat loss coefficient for mass flow rates below a critical value.


1994 ◽  
Vol 116 (1) ◽  
pp. 43-46 ◽  
Author(s):  
S. K. Samdarshi ◽  
S. C. Mullick

A generalized analytical equation for the top heat loss factor of a flat-plate collector with one or more glass covers has been developed. The maximum computational errors resulting from the use of the analytical equation with several simplifications are ± 5 percent compared to numerical solution of the set of heat balance equations. The analytical equation is considerably more accurate than the available semi-empirical equations over the entire range of variables covered. An additional advantage of the proposed technique over the semi-empirical equations is that results can be obtained for different values of sky temperature, using any given correlation for convective heat transfer in the air gap spacings, and for any given values of fluid (air in the present case) properties.


2012 ◽  
Vol 48 (4) ◽  
pp. 248-253 ◽  
Author(s):  
R. R. Avezov ◽  
N. R. Avezova ◽  
O. S. Ruziev ◽  
A. Vakhidov

1991 ◽  
Vol 113 (2) ◽  
pp. 117-122 ◽  
Author(s):  
S. K. Samdarshi ◽  
S. C. Mullick

An analytical equation for the top heat loss factor of a flat-plate collector with double glazing has been developed. The maximum computational errors resulting from the use of this equation are plus or minus three percent compared to numerical solution of the heat balance equations. The equation is considerably more accurate than the currently used semi-empirical equations over the entire range of variables covered. It is found that the computational errors resulting from simplification of the proposed equation by approximation of the individual heat-transfer coefficients are much lower than the errors resulting from the use of semi-empirical equations.


2021 ◽  
Vol 12 (3) ◽  
pp. 216-221
Author(s):  
A. D. Gupta ◽  
◽  
Ashish Gupta ◽  
P. K. Mishra ◽  
Yashi Gupta ◽  
...  

This research investigation was undertaken in ANDUAT, Kumarganj, Ayodhya, Uttar Pradesh, India to study the numerical optimization of natural convection heat suppression in a solar flat plate collector with straight fins. Optimal characteristics of an array of thin fins attached on the absorber plat were obtained by Particle Swarm Optimization algorithm (PSOA). Free convection considered dominant in the cavity. Governing equations contained continuity; momentum and energy are discretized by finite volume method. The medium is considered incompressible, whose free convection is dominant and Boussinesq approximation is applied. A simplified model of real systems is applied with free convection. Free convection problem is solved by SIMPLER algorithm. Two confined cavities with aspect ratios 30 and 60 are considered as flat plate solar collectors. The results indicate that significant reduction on the free convection heat loss can be obtained from solar flat plate collector by using plate fins, and an optimal plate fins configuration exit for minimal natural convection heat loss for a given range of Rayleigh number. Reduction of up to a maximum of 25% at 0 inclination angle was observed in aspect ratio 30. Results showed PSOA is able to obtain characteristics of attached adiabatic fins on the absorber plate also it can obtain optimal inclination angle of cavity to decrease heat losses from solar collectors. The results obtained provide a novel approach for improving design of flat plate solar collectors for optimal performance.


1988 ◽  
Vol 110 (4) ◽  
pp. 262-267 ◽  
Author(s):  
S. C. Mullick ◽  
S. K. Samdarshi

A different approach to evaluate the top heat loss factor of a flat plate solar collector with a single glass cover is proposed. The equation for the heat loss factor in the analytical form is employed instead of the semi-empirical form hitherto employed for solar collectors. The glass cover temperature is, however, estimated by an empirical relation. (This relation replaces the empirical relation for the factor f of the earlier work). Values of the top heat loss factor calculated by this simple technique are within 3 percent (maximum error) of those obtained by iterative solution of the heat balance equations. There is an improvement in accuracy by a factor greater than five over the current semi-empirical equations. The range of variables covered is 50° C to 150° C in absorber plate temperature, 0.1 to 0.95 in absorber coating emittance, and 5 W/m2C to 45 W/m2C in wind heat-transfer coefficient. The effect of variation in air properties with temperature has been taken into account.


Sign in / Sign up

Export Citation Format

Share Document