Enhanced radioluminescent nuclear battery by optimizing structural design of the phosphor layer

2018 ◽  
Vol 42 (4) ◽  
pp. 1729-1737 ◽  
Author(s):  
Zhiheng Xu ◽  
Yunpeng Liu ◽  
Zhengrong Zhang ◽  
Wang Chen ◽  
Zicheng Yuan ◽  
...  
Author(s):  
Tongxin Jiang ◽  
Zhiheng Xu ◽  
Xiaobin Tang ◽  
Zicheng Yuan ◽  
Hongyu Wang ◽  
...  

Author(s):  
James F. Mancuso ◽  
William B. Maxwell ◽  
Russell E. Camp ◽  
Mark H. Ellisman

The imaging requirements for 1000 line CCD camera systems include resolution, sensitivity, and field of view. In electronic camera systems these characteristics are determined primarily by the performance of the electro-optic interface. This component converts the electron image into a light image which is ultimately received by a camera sensor.Light production in the interface occurs when high energy electrons strike a phosphor or scintillator. Resolution is limited by electron scattering and absorption. For a constant resolution, more energy deposition occurs in denser phosphors (Figure 1). In this respect, high density x-ray phosphors such as Gd2O2S are better than ZnS based cathode ray tube phosphors. Scintillating fiber optics can be used instead of a discrete phosphor layer. The resolution of scintillating fiber optics that are used in x-ray imaging exceed 20 1p/mm and can be made very large. An example of a digital TEM image using a scintillating fiber optic plate is shown in Figure 2.


Author(s):  
N. Mori ◽  
T. Oikawa ◽  
Y. Harada ◽  
J. Miyahara ◽  
T. Matsuo

The Imaging Plate (IP) is a new type imaging device, which was developed for diagnostic x ray imaging. We have reported that usage of the IP for a TEM has many merits; those are high sensitivity, wide dynamic range, and good linearity. However in the previous report the reading system was prototype drum-type-scanner, and IP was also experimentally made, which phosphor layer was 50μm thick with no protective layer. So special care was needed to handle them, and they were used only to make sure the basic characteristics. In this article we report the result of newly developed reading, printing system and high resolution IP for practical use. We mainly discuss the characteristics of the IP here. (Precise performance concerned with the reader and other system are reported in the other article.)Fig.1 shows the schematic cross section of the IP. The IP consists of three parts; protective layer, phosphor layer and support.


2011 ◽  
Vol 131 (3) ◽  
pp. 275-282
Author(s):  
Kenta Seki ◽  
Hiroaki Matsuura ◽  
Makoto Iwasaki ◽  
Hiromu Hirai ◽  
Soichi Tohyama

PCI Journal ◽  
1965 ◽  
Vol 10 (1) ◽  
pp. 91-94
Author(s):  
Felix Kulka

2020 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
El Mehdi Echebba ◽  
Hasnae Boubel ◽  
Oumnia Elmrabet ◽  
Mohamed Rougui

Abstract In this paper, an evaluation was tried for the impact of structural design on structural response. Several situations are foreseen as the possibilities of changing the distribution of the structural elements (sails, columns, etc.), the width of the structure and the number of floors indicates the adapted type of bracing for a given structure by referring only to its Geometric dimensions. This was done by studying the effect of the technical design of the building on the natural frequency of the structure with the study of the influence of the distribution of the structural elements on the seismic response of the building, taking into account of the requirements of the Moroccan earthquake regulations 2000/2011 and using the ANSYS APDL and Robot Structural Analysis software.


AIAA Journal ◽  
2001 ◽  
Vol 39 ◽  
pp. 721-728
Author(s):  
Kuo-Shen Chen ◽  
S. Mark Spearing ◽  
Noel N. Nemeth

Sign in / Sign up

Export Citation Format

Share Document