The comparative performance of seismic response spectrum combination rules in building analysis

1983 ◽  
Vol 11 (5) ◽  
pp. 623-647 ◽  
Author(s):  
B. F. Maison ◽  
C. F. Neuss ◽  
K. Kasai
2021 ◽  
Vol 11 (3) ◽  
pp. 906
Author(s):  
Payam Tehrani ◽  
Denis Mitchell

The seismic responses of continuous multi-span reinforced concrete (RC) bridges were predicted using inelastic time history analyses (ITHA) and incremental dynamic analysis (IDA). Some important issues in ITHA were studied in this research, including: the effects of using artificial and natural records on predictions of the mean seismic demands, effects of displacement directions on predictions of the mean seismic response, the use of 2D analysis with combination rules for prediction of the response obtained using 3D analysis, and prediction of the maximum radial displacement demands compared to the displacements obtained along the principal axes of the bridges. In addition, IDA was conducted and predictions were obtained at different damage states. These issues were investigated for the case of regular and irregular bridges using three different sets of natural and artificial records. The results indicated that the use of natural and artificial records typically resulted in similar predictions for the cases studied. The effect of displacement direction was important in predicting the mean seismic response. It was shown that 2D analyses with the combination rules resulted in good predictions of the radial displacement demands obtained from 3D analyses. The use of artificial records in IDA resulted in good prediction of the median collapse capacity.


2014 ◽  
Vol 539 ◽  
pp. 731-735 ◽  
Author(s):  
Yu Chen

In this thesis, based on the design of a 140+90m span unusual single tower and single cable plane cable-stayed bridge, free vibration characteristics and seismic response are investigated; three dimensional finite element models of a single tower cable-stayed bridge with and without the pile-soil-structure interaction are established respectively by utilizing finite element software MIDAS/CIVIL, seismic response of Response spectrum and Earthquake schedule are analyzed respectively and compared. By the comparison of the data analysis, for small stiffness span cable-stayed bridge, the pile-soil-structure interaction can not be ignored with calculation and analysis of seismic response.


2016 ◽  
Vol 858 ◽  
pp. 157-162 ◽  
Author(s):  
Hao Lei Wang ◽  
Feng Jie Ma ◽  
Chao Zhu

In order to break through the limitation of the width of river, depth of water, channel and etc., it is an optimal choice to construct a long-span suspension bridge. In a suspension bridge, the main cable is the major bearing member; and the use of super high strength cable wire can lighten the dead weight and obtain an economical design. 1960 Mpa cable wire is adopted by an under-construction suspension bridge, namely Ni-Zhou Channel Bridge, for the first time in China. In this paper, taking the Ni-Zhou Channel Bridge as a case-study, comparative analyses on dynamic characteristic and seismic response of long-span suspension bridge with 1960 Mpa cable wire are performed. Firstly, dynamic calculating model for Ni-Zhou Channel Bridge is built and its dynamic characteristics are studied; then by using response spectrum and time history analysis method, seismic response of Ni-Zhou Channel Bridge is investigated on the basis of design response spectrum and artificial seismic ground motions; finally, the energy dissipation performances of a seismic protection devices (viscous damper) are also discussed. The results show that long-span suspension bridge with 1960 Mpa cable wire has a longer natural vibration period; the use of viscous damper can effectively reduce the peak value of bending moment in stiffening girder. This paper can provide references for the project’s construction.


Author(s):  
Deepak Jain

Abstract: Floating column building is a new fascination for engineers. As floating column buildings provides more space and good aesthetics to the building. But have high structural challenges, when a floating column is provided in a multi-story building in a high seismic zone. This paper reviews several studies conducted on the floating column building and its behavior under seismic loads. This paper studies that floating column building are vulnerable to the high seismic zones. The risk of damage also depends on the shape and size of the buildings.The ductile detailing of the joints is the promising solution for immediate failure of such buildings. Keywords: Floating Column, Response spectrum analysis. Vulnerable, damage, multi-story


Author(s):  
Bikramjit Singh Antaal ◽  
Yogeshwar Hari ◽  
Dennis K. Williams

This paper describes the finite element considerations employed in a seismic response spectrum analysis of a skirt supported, liquid containing pressure vessel. Like many axisymmetric cylindrical vessels, the gross seismic response to an input response spectrum can be categorized by a simplified lump mass model that includes both the mass of the vessel proper in combination with the associated mass of multiple fluid levels. This simplified response may be utilized to determine the initial sizing of the supporting configuration, such as a skirt, but lacks the ability to properly address the fluid-structure interaction that creates sloshing loads on the vessel walls. The most obvious method to address the fluid-structure interaction when considering the finite element method is to build a three-dimensional model of the vessel proper, including, but not limited to the shell courses, the top and bottom heads (for a vertical vessel), and the support skirt. The inclusion of the fluid effects may now be incorporated with a “contained fluid” finite element, however, for vessels of any significant volume, the number of finite elements can easily exceed 100,000 and the number of degrees of freedom can sore from as few as 300,000 to as many as 500,000 or more. While these types of finite element analysis problems can be solved with today’s computer hardware and software, it is not desirable in any analysis to have that volume of information that has to be reviewed and approved in a highly regulated nuclear QA environment (if at all possible). With these items in mind, the methodology described in this paper seeks to minimize the number of degrees of freedom associated with a response spectrum analysis of a liquid filled, skirt supported vertical pressure vessel. The input response spectra are almost always provided in Cartesian coordinates, while many, if not most liquid containing pressure vessels are almost always axisymmetric in geometry without having benefit of being subjected to an axisymmetric load (acceleration in this case) due to the specified seismic event. The use of harmonic finite elements for both the vessel structure and the contained fluid medium permit the efficiencies associated with an axisymmetric geometry to be leveraged when the seismic response spectrum is formulated in terms of a Fourier series and combined to regain the effects of the two orthogonal, horizontally applied accelerations as a function of frequency. The end result as discussed and shown in this paper is a finite element model that permits a dense mesh of both the fluid and the structure, while economizing on the number of simultaneous equations required to be solved by the chosen finite element analysis.


Sign in / Sign up

Export Citation Format