Dynamic loading tests and seismic response analysis of a stud‐type damper composed of multiple friction units with disc springs

2020 ◽  
Vol 49 (13) ◽  
pp. 1259-1280
Author(s):  
Takeshi Sano ◽  
Kazutaka Shirai ◽  
Yasumasa Suzui ◽  
Yoshikazu Utsumi
Author(s):  
Tsuyoshi Fukasawa ◽  
Shigeki Okamura ◽  
Takahiro Somaki ◽  
Takayuki Miyagawa ◽  
Masato Uchita ◽  
...  

This paper describes that the analytical model for the three-dimensional isolation system [1], which consists of thick rubber bearings, disc springs and oil dampers, is created through loading tests. The new-type analytical models of each element are proposed to improve the prediction accuracy of the seismic response analysis. The concept of the three-dimensional isolation system has been proposed to ensure the structural integrity for large reactor vessels. The primary specifications of the three-dimensional isolation system are a horizontal natural period of 3.4 s and a vertical natural period of 0.33 s. The investigations of horizontal isolation performances have been conducted for the various types of isolation devices, beginning with rubber bearings, whereas the previous studies focused on the vertical isolation performances are only a few. Hence, isolation characteristics, such as restoring force and damping force, should be clarified by loading tests using vertical seismic isolation elements, and analytical model to assess the seismic response should be identified on the basis of the loading test results. This paper presents a new analytical model with providing of the differential equations to improve the prediction accuracy and demonstrates the seismic performance, including beyond-design-basis ground motion, for the three-dimensional isolation system by the seismic response analysis.


1999 ◽  
Vol 5 (9) ◽  
pp. 71-76
Author(s):  
Takao MATSUMURA ◽  
Shinichiro ASANO ◽  
Jun YAMADA ◽  
Masao KOBA ◽  
Koji ITO ◽  
...  

2014 ◽  
Vol 711 ◽  
pp. 520-524 ◽  
Author(s):  
Huan Qin Liu ◽  
Wei Bin Li ◽  
Ruo Yang Wu ◽  
Lin Fei Yan

Based on one 240-meter-high special-shaped RC chimney, the structure’s dynamic performance and elastic-plastic seismic response analysis has been studied in detail. From the analysis, it demonstrates the weak areas in the chimney. The interlayer displacement angle about corresponding performance points under four kinds of loading mode were also acuired, and the response of four loading patterns were analyzed.


2013 ◽  
Vol 778 ◽  
pp. 714-721
Author(s):  
Katsuhiko Kohara ◽  
Takeshi Nomura ◽  
Kazuyoshi Koumoto

Our research team developed a brace type and an angle brace type of the visco-elastic damper on seismic-response controlled structure for timber structure. We performed various dependence evaluations by the materials examination of the styrene olefin-based visco-elastic body which we developed newly. We made a structural model using the performance that loading tests in timber frame. We inspected the validity of the structural model. In addition, we built a technical support system for damper setting by the time history response analysis so that a general design architect was easy to use the damper. We could express dynamics properties of visco-elastic body properties by Voigt model, and the structural model almost accorded with an examination property value. We made a structural model of the whole frame system by Kb of installation rigidity obtained from loading tests in timber frame. Because a design level almost accorded with experimental value, the validity of the frame design on seismic-response controlled structure in consideration of the dependence (distortion, frequency, temperature) of the visco-elastic body was confirmed. This visco-elastic damper on seismic-response controlled structure acquired minister authorization of Ministry of Land, Infrastructure and Transport. In addition, this damper acquired the certification of the Japan Building Disaster Prevention Association.


2013 ◽  
Vol 663 ◽  
pp. 87-91
Author(s):  
Ying Bo Pang

As an effective way of passive damping, isolation technology has been widely used in all types of building structures. Currently, for its theoretical analysis, it usually follows the rigid foundation assumption and ignores soil-structure interaction, which results in calculation results distortion in conducting seismic response analysis. In this paper, three-dimensional finite element method is used to establish finite element analysis model of large chassis single-tower base isolation structure which considers and do not consider soil-structure interaction. The calculation results show that: after considering soil-structure interaction, the dynamic characteristics of the isolation structure, and seismic response are subject to varying degrees of impact.


Sign in / Sign up

Export Citation Format

Share Document