Seismic response predictions of multi-span steel bridges through pushover analysis

2003 ◽  
Vol 32 (8) ◽  
pp. 1259-1274 ◽  
Author(s):  
Yi Zheng ◽  
Tsutomu Usami ◽  
Hanbin Ge
2018 ◽  
Vol 162 ◽  
pp. 04019 ◽  
Author(s):  
Sardasht Sardar ◽  
Ako Hama

Numerous recent studies have assessed the effect of P-Delta on the structures. This paper investigates the effect of P-Delta in seismic response of structures with different heights. For indicating the effect of P-Delta, nonlinear static analysis (pushover analysis) and nonlinear dynamic analysis (Time history analysis) were conducted by using finite element software. The results showing that the P-Delta has a significant impact on the structural behavior mainly on the peak amplitude of building when the height of the structures increased. In addition, comparison has been made between concrete and steel structure.


2009 ◽  
Vol 13 (8) ◽  
pp. 1089-1100 ◽  
Author(s):  
Angelo D'Ambrisi ◽  
Mario De Stefano ◽  
Marco Tanganelli

2010 ◽  
Vol 163-167 ◽  
pp. 4076-4082
Author(s):  
Ying Na Mu ◽  
Lei Shi ◽  
Zhe Zhang

Because the traditional pushover analysis can not take the contributions of higher modes into account, To overcome this limitation, a modal pushover analysis procedure (MPA) is proposed by some researchers, which can involve the combination of multi-mode contributions to response. In this paper, much improvement on MPA procedure is made with consideration of the changes of seismic response after structural yielding and anew distribution of inertia forces. The method is verified by one example of bridge structure. It is concluded that the improvement part-sectionalized MPA presented in this paper has high accuracy.


Author(s):  
Maria Vathi ◽  
Spyros A. Karamanos

Unanchored liquid storage tanks under strong earthquake loading tend to uplift. In the present study, the effects of base uplifting on the seismic response of unanchored tanks are presented with emphasis on elephant’s foot buckling, base plate strength and shell-to-base connection capacity. Towards this purpose, base uplifting mechanics is analyzed through a detailed simulation of the tank using non-linear finite elements, and a static pushover analysis is conducted that considers the hydrodynamic pressure distribution due to seismic loading on the tank wall and the base plate. The uplifting provisions from EN 1998-4 and API 650 Appendix E standards are briefly described. Numerical results for a typical 27.8-meter-diameter steel tank are compared with the above design provisions.


Sign in / Sign up

Export Citation Format

Share Document