scholarly journals Investigation of Transverse Relaxation Rate Distribution via Magnetic Resonance Imaging: Impact of Electrode Formation

2020 ◽  
pp. 2000579
Author(s):  
Roland Balbierer ◽  
Philipp Seegert ◽  
Sabrina Herberger ◽  
Thomas Wetzel ◽  
Hermann Nirschl ◽  
...  
2003 ◽  
Vol 3 (3) ◽  
pp. 123-129 ◽  
Author(s):  
G. P. Liney ◽  
A. Heathcote ◽  
A. Jenner ◽  
L. W. Turnbull ◽  
A. W. Beavis

This work describes the feasibility of using a polymer-based tissue equivalent gel for measuring radiation doses in situ. The gel is based on the MAGIC formulation thereby enabling it to be manufactured under normal atmospheric conditions. Its composition has been altered to achieve a similar sensitivity to the more widely used, but technically more difficult to produce, PAG gels. Irradiation of the gel material causes polymerisation of the molecular structure resulting in a shortening of transverse relaxation time (T2), which can be imaged using Magnetic Resonance Imaging (MRI). This work calibrates the radiation response in terms of transverse relaxation rate (R2) and uses this information to provide absolute dose verification in a separate gel, which has been previously irradiated to a known configuration. Results demonstrate that this technique is able to verify radiation doses to within a few percent of delivered intent in three dimensions and with high spatial resolution. This work may be followed by anyone with an interest in the quality assurance of advanced conformal radiotherapy delivery methods.


2015 ◽  
Vol 5 ◽  
pp. 1 ◽  
Author(s):  
Grigorios Gotzamanis ◽  
Roman Kocian ◽  
Pinar S. Özbay ◽  
Manuel Redle ◽  
Spyridon Kollias ◽  
...  

Objectives: This study aims to quantify the response of the transverse relaxation rate of the magnetic resonance (MR) signal of the cerebral tissue in healthy volunteers to the administration of air with step-wise increasing percentage of oxygen. Materials and Methods: The transverse relaxation rate (R2*) of the MR signal was quantified in seven volunteers under respiratory intake of normobaric gas mixtures containing 21, 50, 75, and 100% oxygen, respectively. End-tidal breath composition, arterial blood saturation (SaO2), and heart pulse rate were monitored during the challenge. R2* maps were computed from multi-echo, gradient-echo magnetic resonance imaging (MRI) data, acquired at 3.0T. The average values in the segmented white matter (WM) and gray matter (GM) were tested by the analysis of variance (ANOVA), with Bonferroni post-hoc correction. The GM R2*-reactivity to hyperoxia was modeled using the Hill's equation. Results: Graded hyperoxia resulted in a progressive and significant (P < 0.05) decrease of the R2* in GM. Under normoxia the GM-R2* was 17.2 ± 1.1 s-1. At 75% O2 supply, the R2* had reached a saturation level, with 16.4 ± 0.7 s-1 (P = 0.02), without a significant further decrease for 100% O2. The R2*-response of GM correlated positively with CO2 partial pressure (R = 0.69 ± 0.19) and negatively with SaO2 (R = -0.74 ± 0.17). The WM showed a similar progressive, but non-significant, decrease in the relaxation rates, with an increase in oxygen intake (P = 0.055). The Hill's model predicted a maximum R2* response of the GM, of 3.5%, with half the maximum at 68% oxygen concentration. Conclusions: The GM-R2* responds to hyperoxia in a concentration-dependent manner, suggesting that monitoring and modeling of the R2*-response may provide new oxygenation biomarkers for tumor therapy or assessment of cerebrovascular reactivity in patients.


2000 ◽  
Vol 20 (5) ◽  
pp. 847-860 ◽  
Author(s):  
Ikuhiro Kida ◽  
Richard P. Kennan ◽  
Douglas L. Rothman ◽  
Kevin L. Behar ◽  
Fahmeed Hyder

The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) method, which is sensitive to vascular paramagnetic deoxyhemoglobin, is dependent on regional values of cerebral metabolic rate of oxygen utilization (CMRO2), blood flow (CBF), and volume (CBV). Induced changes in deoxyhemoglobin function as an endogenous contrast agent, which in turn affects the transverse relaxation rates of tissue water that can be measured by gradient-echo and spin-echo sequences in BOLD fMRI. The purpose here was to define the quantitative relation between BOLD signal change and underlying physiologic parameters. To this end, magnetic resonance imaging and spectroscopy methods were used to measure CBF, CMRO2, CBV, and relaxation rates (with gradient-echo and spin-echo sequences) at 7 Tesla in rat sensorimotor cortex, where cerebral activity was altered pharmacologically within the autoregulatory range. The changes in tissue transverse relaxation rates were negatively and linearly correlated with changes in CBF, CMRO2, and CBV. The multiparametric measurements revealed that CBF and CMRO2 are the dominant physiologic parameters that modulate the BOLD fMRI signal, where the ratios of (ΔCMRO2/CMRO2)/(ΔCBF/CBF) and (ΔCBV/CBV)/(ΔCBF/CBF) were 0.86 ± 0.02 and 0.03 ± 0.02, respectively. The calibrated BOLD signals (spatial resolution of 48 μL) from gradient-echo and spin-echo sequences were used to predict changes in CMRO2 using measured changes in CBF, CBV, and transverse relaxation rates. The excellent agreement between measured and predicted values for changes in CMRO2 provides experimental support of the current theory of the BOLD phenomenon. In gradient-echo sequences, BOLD contrast is affected by reversible processes such as static inhomogeneities and slow diffusion, whereas in spin-echo sequences these effects are refocused and are mainly altered by extravascular spin diffusion. This study provides steps by which multiparametric MRI measurements can be used to obtain high-spatial resolution CMRO2 maps.


Blood ◽  
2005 ◽  
Vol 105 (2) ◽  
pp. 855-861 ◽  
Author(s):  
Timothy G. St. Pierre ◽  
Paul R. Clark ◽  
Wanida Chua-anusorn ◽  
Adam J. Fleming ◽  
Gary P. Jeffrey ◽  
...  

AbstractMeasurement of liver iron concentration (LIC) is necessary for a range of iron-loading disorders such as hereditary hemochromatosis, thalassemia, sickle cell disease, aplastic anemia, and myelodysplasia. Currently, chemical analysis of needle biopsy specimens is the most common accepted method of measurement. This study presents a readily available noninvasive method of measuring and imaging LICs in vivo using clinical 1.5-T magnetic resonance imaging units. Mean liver proton transverse relaxation rates (R2) were measured for 105 humans. A value for the LIC for each subject was obtained by chemical assay of a needle biopsy specimen. High degrees of sensitivity and specificity of R2 to biopsy LICs were found at the clinically significant LIC thresholds of 1.8, 3.2, 7.0, and 15.0 mg Fe/g dry tissue. A calibration curve relating liver R2 to LIC has been deduced from the data covering the range of LICs from 0.3 to 42.7 mg Fe/g dry tissue. Proton transverse relaxation rates in aqueous paramagnetic solutions were also measured on each magnetic resonance imaging unit to ensure instrument-independent results. Measurements of proton transverse relaxivity of aqueous MnCl2 phantoms on 13 different magnetic resonance imaging units using the method yielded a coefficient of variation of 2.1%.


Sign in / Sign up

Export Citation Format

Share Document