Determination of inorganic ions in mineral water by gradient elution moving boundary electrophoresis

2010 ◽  
Vol 31 (20) ◽  
pp. 3466-3474 ◽  
Author(s):  
Paul M. Flanigan ◽  
David Ross ◽  
Jonathan G. Shackman
Kerntechnik ◽  
2008 ◽  
Vol 73 (3) ◽  
pp. 122-126 ◽  
Author(s):  
K. Flesch ◽  
R. Gellermann ◽  
J. Gerler ◽  
R. Knappik ◽  
M. Köhler ◽  
...  
Keyword(s):  

2020 ◽  
Vol 17 (1) ◽  
pp. 47-56
Author(s):  
Shun Liu ◽  
Xun Wang ◽  
Kaiping Zou ◽  
Wei Liu ◽  
Cunyu Li ◽  
...  

Background: Zishen Tongguan (ZSTG) capsules were prepared at the Affiliated Hospital of Nanjing University of Chinese Medicine and have been proven to be clinically effective for treating pyelonephritis and benign prostatic hyperplasia. However, the quality standards are not ideal; a comprehensive study of the “quality markers” (Q-markers), the chemicals inherent in traditional Chinese medicine and its preparations, has not been carried out. Experimental Methods: In this paper, a sensitive and specific ultra-high-performance liquid chromatographictandem mass spectrometry (UHPLC-MS/MS) method was developed for the simultaneous determination of eight potential Q-markers of ZSTG, including timosaponin A3, berberine, jatrorrhizine, phellodendrine, palmatine, mangiferin, neomangiferin, and timosaponin BII. A Kromasil 100-3.5 C18 column was used with a mobile phase of 0.2% formic acid with acetonitrile, and gradient elution at a flow rate of 0.2 mL/min was achieved in 13 minutes and used for separation. Detection was performed in positive/negative mode with multiple reaction monitoring (MRM). Results: The analytical method was validated in terms of the sensitivity, linearity, accuracy, precision, repeatability, stability and recovery. The method established here was successfully applied to study the potential Q-markers in 8 batches of commercial samples, which demonstrated its use in improving the quality control of ZSTG. Conclusion: The developed method had high repeatability and accuracy and was suitable for the simultaneous analysis of multiple Q-markers, which may provide a new basis for the comprehensive assessment and overall quality control of ZSTG.


2019 ◽  
Vol 15 (5) ◽  
pp. 505-510
Author(s):  
Yanjuan Zheng ◽  
Qiushi Peng ◽  
Rui Dong ◽  
Tingyu Chen ◽  
Yi Bao ◽  
...  

Introduction: A rapid, and accurate Ultra Performance Liquid Chromatography (UPLC) method was developed to simultaneously analyze Methocarbamol, Paracetamol and the related substances Materials and Methods: Waters ACQUITY UPLC® BEH Phenyl C18 column was used in conjunction with UV detection at 225nm. Gradient elution with 0.05M, pH 6 phosphate buffer and acetonitrile flow at 0.3mL /min rate were used to separate the substances. The retention times for 4-Aminopheno, Paracetamol, Guaifenesin, Methocarbamol, and 4-Chloroacetanilide were 1.319 minute, 2.224 minute, 4.467 minute, 4.769 minute and 5.433 minute respectively. The concentration was linear in the range of 2-100 µg/ml for Methocarbamol, and 1-100 µg/mL for Paracetamol. The percentage recoveries were between 99.28±1.23% to 100.57±0.99% for Methocarbamol, and between 99.08±1.23% to 101.23±1.39% for Paracetamol. Results and Discussion: The validated optimal protocol is robust and accurate for simultaneous analysis of Methocarbamol, Paracetamol and the related substances, applicable for bulk powder as well as pharmaceutical formulation. Conclusion: In this paper, a highly sensitive, accurate, and precise UPLC method with UV-Vis detection was developed and validated for quality control of MET and PAR in bulk as well as in pharmaceutical preparations.


2020 ◽  
Vol 17 (1) ◽  
pp. 95-105
Author(s):  
Ramji Rathod ◽  
Faraat Ali ◽  
Amrish Chandra ◽  
Robin Kumar ◽  
Meenakshi Dahiya ◽  
...  

Background: A simple and sensitive Ultra Performance Liquid Chromatography-Mass Spectrometry method was developed and validated to measure the concentrations of Alogliptin (ALO), Linagliptin (LIN), Saxagliptin (SAX), and Sitagliptin (SIT) using Pioglitazone (PIO) as an internal standard. Methods: Chromatographic separation of six gliptins was achieved on a C-18 column (100×2.1 mm, 2.7 μm) using a mobile phase consisting of formic acid in water, 0.1%v/v: acetonitrile in gradient elution. Electrospray ionization (ESI) source was operated in the positive ion mode. Targeted MS/MS mode on a QTOF MS was used to quantify the drug utilizing the transitions of 340.1(m/z), 473.2 (m/z), 316.2 (m/z), 408.1 (m/z), and 357.1 (m/z) for ALO, LIN, SAX, SIT and PIO respectively. Results: As per ICH Q2R1 guidelines, a detailed validation of the method was carried out and the standard curves were found to be linear over the concentration ranges of 1516.0-4548.1 ng mL-1, 519.8- 1559.4 ng mL-1, 1531.4-4594.3 ng mL-1and 1519.6-4558.8 ng mL-1 for ALO, LIN, SAX and SIT respectively. Precision and accuracy results were within the acceptable limits. The mean recovery was found to be 98.8 _ 0.76 % (GEM), 102.2 _ 1.59 % (LIN), 95.3 _ 2.74 % (SAX) and 99.2 _ 1.75 % (SIT) respectively. Conclusions: The optimized validated UPLC QTOF-MS/MS method offered the advantage of shorter analytical times and higher sensitivity and selectivity. The optimized method is suitable for application in quantitative analysis of pharmaceutical dosage forms for QC laboratory.


2020 ◽  
Vol 16 (8) ◽  
pp. 1059-1067
Author(s):  
Jéssica Maurício Batista ◽  
Christian Fernandes

Background: Linezolid is a synthetic broad-spectrum antibacterial belonging to the class of oxazolidinones. Linezolid for intravenous infusion is isotonized with dextrose. In acidic environment, the dehydration of dextrose produces furan derivatives, 5-hydroxymethylfurfural (5-HMF) being the main one. The determination of this degradation product is of fundamental importance, since there is evidence it is cytotoxic, genotoxic, mutagenic and carcinogenic. However, there is no official method for the determination of 5-HMF in drug products. Objective: The aim of this study was to develop and validate a high performance liquid chromatographic method to quantify 5-HMF in injection of linezolid. Methods: The chromatographic separation, after optimization, was performed on C18 (150 x 4.6 mm, 5 μm) column. Mobile phase was composed of 14 mM potassium phosphate buffer pH 3.0 ([H+] = 1.0 x 10-3) and methanol in gradient elution at 1.0 mL min-1. The injection volume was 10 μL and detection was performed at 285 nm. Results: The method was optimized and validated, showing selectivity, linearity in the range from 0.075 to 9.0 μg mL-1, precision (RSD ≤ 2.0%), accuracy (mean recovery of 100.07%) and robustness for temperature and pH variation. Conclusion: The method was shown to be adequate to determine 5-HMF in injection containing linezolid in routine analysis.


2019 ◽  
Vol 15 (2) ◽  
pp. 130-137
Author(s):  
Hui Jiang ◽  
Lianhao Fu ◽  
Yu Wang ◽  
Shaozhi Wang ◽  
Xiaoxu Zhang ◽  
...  

Background: Jingzhiguanxin (JZGX) tablet, a traditional Chinese prescription, is commonly used for treating coronary heart disease and angina pectoris in the clinic. There are six active components (Danshensu (DSS), Protocatechuic aldehyde (PD), Paeoniflorin (PF), Ferulic acid (FA), Salvianolic acid B (Sal B) and Tanshinone IIA (TA)) in JZGX tablet. </P><P> Objective: In this paper, a simple and reliable method was used for simultaneous determining the six active components by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). Methods: These six active components were separated on an Agilent Zorbax Eclipse XDB-C18 column (150 mmx4.6 mm, 5 µm) at 30 °C. Acetonitrile (A), methanol (B) and 0.5% H3PO4 aqueous solution (C) were used as mobile phase for gradient elution. The flow rate was 1 mL/min and the detection wavelengths were set at 280 nm for DSS, PD and Sal B, 230 nm for PF, 320 nm for FA and 270 nm for TA, respectively. Results: All of the six components showed good linearity regressions (r2≥0.9997) in the detected concentration range. The recovery rates and coefficient of variation (CV) for all analytes were 98.66%- 100.18% and 0.75%-1.89%, respectively. This method was successfully applied to simultaneously determine the six components in JZGX tablet from different batches and manufacturers. Conclusion: The validated method can be used in routine quality control analysis of JZGX tablet without any interference.


2019 ◽  
Vol 15 (2) ◽  
pp. 121-129
Author(s):  
Zhi Rao ◽  
Bo-xia Li ◽  
Yong-Wen Jin ◽  
Wen-Kou ◽  
Yan-rong Ma ◽  
...  

Background: Imatinib (IM) is a chemotherapy medication metabolized by CYP3A4 to Ndesmethyl imatinib (NDI), which shows similar pharmacologic activity to the parent drug. Although methods for determination of IM and/or NDI have been developed extensively, only few observations have been addressed to simultaneously determine IM and NDI in biological tissues such as liver, kidney, heart, brain and bone marrow. Methods: A validated LC-MS/MS method was developed for the quantitative determination of imatinib (IM) and N-desmethyl imatinib (NDI) from rat plasma, bone marrow, brain, heart, liver and kidney. The plasma samples were prepared by protein precipitation, and then the separation of the analytes was achieved using an Agilent Zorbax Eclipse Plus C18 column (4.6 × 100 mm, 3.5 µm) with gradient elution running water (A) and methanol (B). Mass spectrometric detection was achieved by a triplequadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. Results: This method was used to investigate the pharmacokinetics and the tissue distributions in rats following oral administration of 25 mg/kg of IM. The pharmacokinetic profiles suggested that IM and NDI are disappeared faster in rats than human, and the tissue distribution results showed that IM and NDI had good tissue penetration and distribution, except for the brain. This is the first report about the large penetrations of IM and NDI in rat bone marrow. Conclusion: The method demonstrated good sensitivity, accuracy, precision and recovery in assays of IM and NDI in rats. The described assay was successfully applied for the evaluation of pharmacokinetics and distribution in the brain, heart, liver, kidney and bone marrow of IM and NDI after a single oral administration of IM to rats.


1984 ◽  
Vol 49 (10) ◽  
pp. 2349-2354 ◽  
Author(s):  
František Vláčil ◽  
Karel Koňák

The selectivity coefficients of the nitrate and chloride ions and of anionic chloro complexes of Au(III), Rh(III), Pd(II), and Pt(IV) for ion exchange on Spheron DEAE in the chloride form are determined by the dynamic method. the complex anion species formed are identified and the ion exchange nature of the sorption of precious metals on this sorbent is confirmed based on the elution order of the precious metals as determined previously by the column chromatography on Spheron DEAE using hydrochloric acid as the mobile phase. The effect of the presence of perchlorate in the mobile phase during the liquid chromatography of precious metals and during the chromatographic determination of nitrate traces is explained.


Molecules ◽  
2021 ◽  
Vol 26 (15) ◽  
pp. 4505
Author(s):  
Jiahui Sun ◽  
Chunli Gan ◽  
Jing Huang ◽  
Zhenyue Wang ◽  
Chengcui Wu ◽  
...  

A novel analytical method involving high-performance liquid chromatography with evaporative light scattering detection (HPLC-ELSD) was developed for simultaneous determination of 11 phenolic acids and 12 triterpenes in Sanguisorba officinalis L. Chromatographic separation was conducted with gradient elution mode by using a DiamonsilTM C18 column (250 mm × 4.6 mm, 5 μm) with the mobile phase of 0.1% acetic acid water (A) and methanol (B). The drift tube temperature of ELSD was set at 70 °C and the nitrogen cumulative flow rate was 1.6 L/min. The method was fully validated to be linear over a wide concentration range (R2 ≥ 0.9991). The precisions (RSD) were less than 3.0% and the recoveries were between 97.7% and 101.4% for all compounds. The results indicated that this method is accurate and effective for the determination of 23 functional components in Sanguisorba officinalis L. and could also be successfully applied to study the influence of processing method on those functional components in Sanguisorba officinalis L.


2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
Vita Giaccone ◽  
Giuseppe Polizzotto ◽  
Andrea Macaluso ◽  
Gaetano Cammilleri ◽  
Vincenzo Ferrantelli

The aim of our present work was the development of a rapid high-performance liquid chromatography method with electrospray ionization and tandem mass spectrometry detection (LC-ESI-MS/MS) for the determination of several corticosteroids in cosmetic products. Corticosteroids are suspected to be illegally added in cosmetic preparations in order to enhance the curative effect against some skin diseases. Sample preparation step consists in a single extraction with acetonitrile followed by centrifugation and filtration. The compounds were separated by reversed-phase chromatography with water and acetonitrile (both with 0.1% formic acid) gradient elution and detected by ESI-MS positive and negative ionization mode. The method was validated at the validation level of 0.1 mg kg−1. Linearity was studied in the 5–250 μg L−1 range and linear coefficients (r2) were all over 0.99. The accuracy and precision of the method were satisfactory. The LOD ranged from 0.085 to 0.109 mg kg−1 and the LOQ from 0.102 to 0.121 mg kg−1. Mean recoveries for all the analytes were within the range 91.9–99.2%. The developed method is sensitive and useful for detection, quantification, and confirmation of these corticosteroids in cosmetic preparations and can be applied in the analysis of the suspected samples under investigation.


Sign in / Sign up

Export Citation Format

Share Document