High-resolution 2-deoxyglucose mapping of functional cortical columns in mouse barrel cortex

1988 ◽  
Vol 278 (4) ◽  
pp. 555-569 ◽  
Author(s):  
James S. McCasland ◽  
Thomas A. Woolsey
2002 ◽  
Vol 22 (3) ◽  
pp. 353-360 ◽  
Author(s):  
Joseph P. Erinjeri ◽  
Thomas A. Woolsey

The authors evaluated representations of discretely activated, neighboring brain regions using real-time optical intrinsic signals by transcranial imaging with 540-nm and 610-nm broadband illumination of the mouse barrel cortex. Iron filings were glued to two neighboring whiskers (C2 + D2) that were stimulated magnetically, singly and together. Real-time images were collected, averaged, and analyzed statistically. Postmortem filling of arteries with fluorescent beads was shown in relation to histochemical staining of barrels to accurately relate surface changes to functional cortical columns. Significant optical intrinsic signal changes are related to overlapping distributions of arterioles that feed the two separate areas. Activation of adjacent and interacting cortical columns leads not only to increased magnitude of vascular responses in those columns, but also to wider spatial extent of absorption changes occurring principally in areas of cortex fed by vessels upstream of the active cortex. The localization of changing hemoglobin absorption around upstream blood vessels and their vascular domains suggests that propagated vasodilation of upstream parent vessels is greater when vasodilatory signals from separate areas of active cortex converge on common arterioles that feed them.


2018 ◽  
Vol 29 (7) ◽  
pp. 3034-3047
Author(s):  
Jérémy Camon ◽  
Sandrine Hugues ◽  
Melissa A Erlandson ◽  
David Robbe ◽  
Sabria Lagoun ◽  
...  

Abstract Whisker-guided decision making in mice is thought to critically depend on information processing occurring in the primary somatosensory cortex. However, it is not clear if neuronal activity in this “early” sensory region contains information about the timing and speed of motor response. To address this question we designed a new task in which freely moving mice learned to associate a whisker stimulus to reward delivery. The task was tailored in such a way that a wide range of delays between whisker stimulation and reward collection were observed due to differences of motivation and perception. After training, mice were anesthetized and neuronal responses evoked by stimulating trained and untrained whiskers were recorded across several cortical columns of barrel cortex. We found a strong correlation between the delay of the mouse behavioral response and the timing of multiunit activity evoked by the trained whisker, outside its principal cortical column, in layers 4 and 5A but not in layer 2/3. Circuit mapping ex vivo revealed this effect was associated with a weakening of layer 4 to layer 2/3 projection. We conclude that the processes controlling the propagation of key sensory inputs to naive cortical columns and the timing of sensory-guided action are linked.


1967 ◽  
Vol 31 ◽  
pp. 45-46
Author(s):  
Carl Heiles

High-resolution 21-cm line observations in a region aroundlII= 120°,b11= +15°, have revealed four types of structure in the interstellar hydrogen: a smooth background, large sheets of density 2 atoms cm-3, clouds occurring mostly in groups, and ‘Cloudlets’ of a few solar masses and a few parsecs in size; the velocity dispersion in the Cloudlets is only 1 km/sec. Strong temperature variations in the gas are in evidence.


2019 ◽  
Vol 42 ◽  
Author(s):  
J. Alfredo Blakeley-Ruiz ◽  
Carlee S. McClintock ◽  
Ralph Lydic ◽  
Helen A. Baghdoyan ◽  
James J. Choo ◽  
...  

Abstract The Hooks et al. review of microbiota-gut-brain (MGB) literature provides a constructive criticism of the general approaches encompassing MGB research. This commentary extends their review by: (a) highlighting capabilities of advanced systems-biology “-omics” techniques for microbiome research and (b) recommending that combining these high-resolution techniques with intervention-based experimental design may be the path forward for future MGB research.


1994 ◽  
Vol 144 ◽  
pp. 593-596
Author(s):  
O. Bouchard ◽  
S. Koutchmy ◽  
L. November ◽  
J.-C. Vial ◽  
J. B. Zirker

AbstractWe present the results of the analysis of a movie taken over a small field of view in the intermediate corona at a spatial resolution of 0.5“, a temporal resolution of 1 s and a spectral passband of 7 nm. These CCD observations were made at the prime focus of the 3.6 m aperture CFHT telescope during the 1991 total solar eclipse.


1994 ◽  
Vol 144 ◽  
pp. 541-547
Author(s):  
J. Sýkora ◽  
J. Rybák ◽  
P. Ambrož

AbstractHigh resolution images, obtained during July 11, 1991 total solar eclipse, allowed us to estimate the degree of solar corona polarization in the light of FeXIV 530.3 nm emission line and in the white light, as well. Very preliminary analysis reveals remarkable differences in the degree of polarization for both sets of data, particularly as for level of polarization and its distribution around the Sun’s limb.


1988 ◽  
Vol 102 ◽  
pp. 41
Author(s):  
E. Silver ◽  
C. Hailey ◽  
S. Labov ◽  
N. Madden ◽  
D. Landis ◽  
...  

The merits of microcalorimetry below 1°K for high resolution spectroscopy has become widely recognized on theoretical grounds. By combining the high efficiency, broadband spectral sensitivity of traditional photoelectric detectors with the high resolution capabilities characteristic of dispersive spectrometers, the microcalorimeter could potentially revolutionize spectroscopic measurements of astrophysical and laboratory plasmas. In actuality, however, the performance of prototype instruments has fallen short of theoretical predictions and practical detectors are still unavailable for use as laboratory and space-based instruments. These issues are currently being addressed by the new collaborative initiative between LLNL, LBL, U.C.I., U.C.B., and U.C.D.. Microcalorimeters of various types are being developed and tested at temperatures of 1.4, 0.3, and 0.1°K. These include monolithic devices made from NTD Germanium and composite configurations using sapphire substrates with temperature sensors fabricated from NTD Germanium, evaporative films of Germanium-Gold alloy, or material with superconducting transition edges. A new approache to low noise pulse counting electronics has been developed that allows the ultimate speed of the device to be determined solely by the detector thermal response and geometry. Our laboratory studies of the thermal and resistive properties of these and other candidate materials should enable us to characterize the pulse shape and subsequently predict the ultimate performance. We are building a compact adiabatic demagnetization refrigerator for conveniently reaching 0.1°K in the laboratory and for use in future satellite-borne missions. A description of this instrument together with results from our most recent experiments will be presented.


Author(s):  
Robert M. Glaeser

It is well known that a large flux of electrons must pass through a specimen in order to obtain a high resolution image while a smaller particle flux is satisfactory for a low resolution image. The minimum particle flux that is required depends upon the contrast in the image and the signal-to-noise (S/N) ratio at which the data are considered acceptable. For a given S/N associated with statistical fluxtuations, the relationship between contrast and “counting statistics” is s131_eqn1, where C = contrast; r2 is the area of a picture element corresponding to the resolution, r; N is the number of electrons incident per unit area of the specimen; f is the fraction of electrons that contribute to formation of the image, relative to the total number of electrons incident upon the object.


Sign in / Sign up

Export Citation Format

Share Document