scholarly journals Liquid‐based cytology specimen preparation in the era of the COVID‐19 pandemic: The experience of a laboratory in a Portuguese central hospital

2020 ◽  
Vol 128 (12) ◽  
pp. 913-913
Author(s):  
Nuno Jorge Lamas ◽  
Francisca Emanuel Costa ◽  
José Ramón Vizcaíno
2021 ◽  
pp. 1-6
Author(s):  
Katsuhide Ikeda ◽  
Wataru Oboshi ◽  
Yusuke Hashimoto ◽  
Tetsuya Komene ◽  
Yoshitaka Yamaguchi ◽  
...  

<b><i>Introduction:</i></b> Liquid-based cytology (LBC) is increasingly used for nongynecologic applications. However, the cytological preparation of LBC specimens is influenced by the processing technique and the preservative used. In this study, the influence of the processing techniques and preservatives on cell morphology was examined mathematically and statistically. <b><i>Methods:</i></b> Cytological specimens were prepared using the ThinPrep (TP), SurePath (SP), and AutoSmear methods, with 5 different preservative solutions. The cytoplasmic and nuclear areas of Papanicolaou-stained specimens were measured for all samples. <b><i>Results:</i></b> The cytoplasmic and nuclear areas were smaller in cells prepared using the 2 LBC methods, compared to that prepared using the AutoSmear method, irrespective of the preservative used. The cytoplasmic and nuclear areas of cells prepared using the SP method were smaller than those of cells prepared using the TP method, irrespective of the preservative used. There were fewer differences among the cytoplasmic areas of cells prepared with different preservative solutions using the TP method; however, the cytoplasmic areas of cells prepared using the SP method changed with the preservative solution used. <b><i>Conclusions:</i></b> The most significant difference affecting the cytoplasmic and nuclear areas was the processing technique. The TP method increased the cytoplasmic and nuclear areas, while the methanol-based PreservCyt solution enabled the highest enlargement of the cell. LBC is a superior preparation technique for standardization of the specimens. Our results offer a better understanding of methods suitable for specimen preparation for developing precision AI-based diagnosis in cytology.


CytoJournal ◽  
2013 ◽  
Vol 10 ◽  
pp. 9 ◽  
Author(s):  
Muhammad Zulfiqar ◽  
Susan Liu ◽  
Dongping Shi ◽  
Shashi Madan ◽  
Suzanne Jacques ◽  
...  

Only a few cases of adenocarcinoma (ACA) metastatic to the female lower genital tract diagnosed on cervicovaginal Pap smear have been reported during the past several decades. Both conventional and liquid based cytology (LBC) have limited sensitivity and specificity in diagnosing metastatic disease and immunocytochemical (ICC) staining may be needed for confirming the diagnosis. We present two cases of metastatic colorectal ACA diagnosed on cervicovaginal ThinPrep (TP) Pap smears, with one confirmed by ICC staining method. Recognition of extra-uterine malignancy in the cervicovaginal cytology specimen is critical for the disease diagnosis, prognosis, and the treatment. ICC staining performed on the residual LBC specimen is an important methodology to confirm the diagnosis.


Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
L. Gandolfi ◽  
J. Reiffel

Calculations have been performed on the contrast obtainable, using the Scanning Transmission Electron Microscope, in the observation of thick specimens. Recent research indicates a revival of an earlier interest in the observation of thin specimens with the view of comparing the attainable contrast using both types of specimens.Potential for biological applications of scanning transmission electron microscopy has led to a proliferation of the literature concerning specimen preparation methods and the controversy over “to stain or not to stain” in combination with the use of the dark field operating mode and the same choice of technique using bright field mode of operation has not yet been resolved.


Author(s):  
M. Talianker ◽  
D.G. Brandon

A new specimen preparation technique for visualizing macromolecules by conventional transmission electron microscopy has been developed. In this technique the biopolymer-molecule is embedded in a thin monocrystalline gold foil. Such embedding can be performed in the following way: the biopolymer is deposited on an epitaxially-grown thin single-crystal gold film. The molecule is then occluded by further epitaxial growth. In such an epitaxial sandwich an occluded molecule is expected to behave as a crystal-lattice defect and give rise to contrast in the electron microscope.The resolution of the method should be limited only by the precision with which the epitaxially grown gold reflects the details of the molecular structure and, in favorable cases, can approach the lattice resolution limit.In order to estimate the strength of the contrast due to the void-effect arising from occlusion of the DNA-molecule in a gold crystal some calculations were performed.


Author(s):  
F. Thoma ◽  
TH. Koller

Under a variety of electron microscope specimen preparation techniques different forms of chromatin appearance can be distinguished: beads-on-a-string, a 100 Å nucleofilament, a 250 Å fiber and a compact 300 to 500 Å fiber.Using a standardized specimen preparation technique we wanted to find out whether there is any relation between these different forms of chromatin or not. We show that with increasing ionic strength a chromatin fiber consisting of a row of nucleo- somes progressively folds up into a solenoid-like structure with a diameter of about 300 Å.For the preparation of chromatin for electron microscopy the avoidance of stretching artifacts during adsorption to the carbon supports is of utmost importance. The samples are fixed with 0.1% glutaraldehyde at 4°C for at least 12 hrs. The material was usually examined between 24 and 48 hrs after the onset of fixation.


Author(s):  
Jayesh Bellare

Seeing is believing, but only after the sample preparation technique has received a systematic study and a full record is made of the treatment the sample gets.For microstructured liquids and suspensions, fast-freeze thermal fixation and cold-stage microscopy is perhaps the least artifact-laden technique. In the double-film specimen preparation technique, a layer of liquid sample is trapped between 100- and 400-mesh polymer (polyimide, PI) coated grids. Blotting against filter paper drains excess liquid and provides a thin specimen, which is fast-frozen by plunging into liquid nitrogen. This frozen sandwich (Fig. 1) is mounted in a cooling holder and viewed in TEM.Though extremely promising for visualization of liquid microstructures, this double-film technique suffers from a) ireproducibility and nonuniformity of sample thickness, b) low yield of imageable grid squares and c) nonuniform spatial distribution of particulates, which results in fewer being imaged.


Author(s):  
Tokio Nei ◽  
Haruo Yotsumoto ◽  
Yoichi Hasegawa ◽  
Yuji Nagasawa

In order to observe biological specimens in their native state, that is, still containing their water content, various methods of specimen preparation have been used, the principal two of which are the chamber method and the freeze method.Using its recently developed cold stage for installation in the pre-evacuation chamber of a scanning electron microscope, we have succeeded in directly observing a biological specimen in its frozen state without the need for such conventional specimen preparation techniques as drying and metallic vacuum evaporation. (Echlin, too, has reported on the observation of surface structures using the same freeze method.)In the experiment referred to herein, a small sliced specimen was place in the specimen holder. After it was rapidly frozen by freon cooled with liquid nitrogen, it was inserted into the cold stage of the specimen chamber.


Sign in / Sign up

Export Citation Format

Share Document