Assignment of absolute configuration and optical purity determination of (R)- and (S)-econazole nitrate by enantioselective HPLC: Method development and application

Chirality ◽  
1994 ◽  
Vol 6 (4) ◽  
pp. 261-269 ◽  
Author(s):  
Michael Lämmerhofer ◽  
Wolfgang Lindner
2012 ◽  
Vol 2 (2) ◽  
pp. 364-367 ◽  
Author(s):  
Saida Naik Dheeravath ◽  
◽  
Kasani Ramadevi ◽  
Zilla Saraswathi ◽  
Dheeravath Maniklal ◽  
...  

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (06) ◽  
pp. 20-23
Author(s):  
S Sahoo ◽  
◽  
P. K. Panda ◽  
S. K. Mishra

A simple, fast, accurate and precise reverse phase HPLC method is developed and described for the determination of ramelteon in tablet dosage form. Chromatography was carried on an ODS column using a mixture of acetonitrile and phosphate buffer pH 7.0 (35:65 V/V) as the mobile phase at a flow rate of 1.0 mL/min with detection at 286 nm. The retention time of the drug was 7.7 min. The procedure was validated for linearity, precision, accuracy, and robustness. The developed method was validated for linearity from 50 to 150% which shows the method is quite linear with a correlation coefficient of 0.999, for precision which includes system precision, method precision, intraday and by another analyst on another day, and accuracy. The %RSD for system precision was observed to be 1.1, whereas the method precision was observed to be 0.2. The % recovery from ‘accuracy’ studies yielded the recovery of 99.7-101.5% which indicates the capability of the method, and finally for robustness that includes studies w.r.t. change in flow rate, the percentage of organic modifier and pH. As per ICH guidelines, method validation results are in good agreement. The proposed method was simple, sensitive, precise and accurate.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (02) ◽  
pp. 16-20
Author(s):  
L Mohankrishna ◽  
◽  
P. J. Reddy ◽  
B. P Reddy. ◽  
P. Navya

A sensitive and precise HPLC procedure has been developed for the assay of amphotericin B in bulk samples and pharmaceutical formulations by using a C18 column [Kromosil, C18, (5 µm, 4.6mm x 250 mm; Make. Waters)], and mobile phase combination is 1% formic acid in water and acetonitrile in ratio of 45:55 V/V. The procedure has been validated as per the ICH guidelines. The λmax of detection was fixed at 407 nm, so that there was less interference from mobile phase with highest sensitivity according to UV analysis. Calibration plots were linear in the range of 10-100 µg/mL and the LOD and LOQ were 0.02 µg/mL and 0.06 µg/mL respectively. The high recovery and low relative standard deviation confirm the suitability of the method for routine quality control determination of amphotericin B in different formulations.


Author(s):  
A. Tanuja ◽  
S. Ganapaty ◽  
Varanasi S N Murthy

The current work aims to establish a novel and advanced reverse phase isocratic liquid chromatography system followed by validation and to conduct stability analysis in active pharmaceutical ingredients and formulations for the quantification of Solifenacin Succinate. The optimized elution was achieved with column Sunfire C8 (4.6 x 150mm, 5µm), using the mobile phase of Buffer: Methanol: Acetonitrile in the composition ratio of 45:45:10 v/v. The wavelength of detection was selected as 220nm with 1.0ml/ min flow rate and 30μl injection volume. The retention time of Solifenacin Succinate was found 2.94 min respectively. The method developed has been validated for various analytical parameters according to ICH guidelines. The Linearity was attained at 20 to100 μg/ml of concentration range. The established method was proved as reproducible. The Assay was obtained as 100.40%. The degradation studies were carried out at all degradative conditions and the results of degradation studies denote that the current method was specific, reliable, and economical. Hence, the developed method can be applied for the qualitative and quantitative determination of the selected drug and its commercial formulations.


2012 ◽  
Vol 2012 ◽  
pp. 1-4 ◽  
Author(s):  
Shravan Bankey ◽  
Ganesh Tapadiya ◽  
Jasvant Lamale ◽  
Deepti Jain ◽  
Shweta Saboo ◽  
...  

A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant.


Sign in / Sign up

Export Citation Format

Share Document