ChemInform Abstract: AMINO GROUP BLOCKING. IMPROVED METHOD FOR N-PHTHALOYLATION USING N-(ETHOXYCARBONYL)PHTHALIMIDE

1983 ◽  
Vol 14 (40) ◽  
Author(s):  
C. R. MCARTHUR ◽  
P. M. WORSTER ◽  
A. U. OKON
1983 ◽  
Vol 13 (4) ◽  
pp. 311-318 ◽  
Author(s):  
Colin R. Mcarthur ◽  
Paul M. Worster ◽  
Augustine U. Okon

1983 ◽  
Vol 13 (5) ◽  
pp. 393-401 ◽  
Author(s):  
Colin R. Mcarthur ◽  
Paul M. Worster ◽  
Augustine U. Okon

2013 ◽  
Vol 781-784 ◽  
pp. 287-290 ◽  
Author(s):  
Rui Liu ◽  
Hong Li ◽  
Wen Yan Ma

Methodology has been sought towards 1,4-naphthoquinone bearing amino group and hydroxyl group in the quinonoid ring. In the first of these objectives, 2-Hydroxy-3-nitro-1,4-naphthoquinone was synthesized by two kinds of improved method giving moderate yield. Then treatment of 2-hydroxy-3-nitro-1,4-naphthoquinone with stannous chloride in aqueous medium afforded 2-hydroxy-3-amino-1,4-naphthoquinone. The chemical structure of the product obtained by the process of the present study was verified by IR and NMR.


Author(s):  
E.A. Fischione ◽  
P.E. Fischione ◽  
J.J. Haugh ◽  
M.G. Burke

A common requirement for both Atom Probe Field-Ion Microscopy (APFIM) and Scanning Tunnelling Microscopy (STM) is a sharp pointed tip for use as either the specimen (APFIM) or the probe (STM). Traditionally, tips have been prepared by either chemical or electropolishing techniques. Recently, ion-milling has been successfully employed in the production of APFIM tips [1]. Conventional electropolishing techniques are applicable to a wide variety of metals, but generally require careful manual adjustments during the polishing process and may also be time-consuming. In order to reduce the time and effort involved in the preparation process, a compact, self-contained polishing unit has been developed. This system is based upon the conventional two-stage electropolishing technique in which the specimen/tip blank is first locally thinned or “necked”, and subsequently electropolished until separation occurs.[2,3] The result of this process is the production of two APFIM or STM tips. A mechanized polishing unit that provides these functions while automatically maintaining alignment has been designed and developed.


Author(s):  
J. C. Fanning ◽  
J. F. White ◽  
R. Polewski ◽  
E. G. Cleary

Elastic tissue is an important component of the walls of arteries and veins, of skin, of the lungs and in lesser amounts, of many other tissues. It is responsible for the rubber-like properties of the arteries and for the normal texture of young skin. It undergoes changes in a number of important diseases such as atherosclerosis and emphysema and on exposure of skin to sunlight.We have recently described methods for the localizationof elastic tissue components in normal animal and human tissues. In the study of developing and diseased tissues it is often not possible to obtain samples which have been optimally prepared for immuno-electron microscopy. Sometimes there is also a need to examine retrospectively samples collected some years previously. We have therefore developed modifications to our published methods to allow examination of human and animal tissue samples obtained at surgery or during post mortem which have subsequently been: 1. stored frozen at -35° or -70°C for biochemical examination; 2.


Sign in / Sign up

Export Citation Format

Share Document