A differential model for a countercurrent extractor column with non-constant flow rates, interfacial area per unit volume and axial dispersion coefficients

1987 ◽  
Vol 10 (1) ◽  
pp. 375-382
Author(s):  
A. E. Cornelissen ◽  
J. Grievink ◽  
L. H. Toneman
1983 ◽  
Vol 48 (3) ◽  
pp. 842-853
Author(s):  
Kurt Winkler ◽  
František Kaštánek ◽  
Jan Kratochvíl

Specific gas-liquid interfacial area in flow tubes 70 mm in diameter of the length 725 and 1 450 mm resp. containing various swirl bodies were measured for concurrent upward flow in the ranges of average gas (air) velocities 11 to 35 ms-1 and liquid flow rates 13 to 80 m3 m-2 h-1 using the method of CO2 absorption into NaOH solutions. Two different flow regimes were observed: slug flow swirled annular-mist flow. In the latter case the determination was carried out separately for the film and spray flow components, respectively. The obtained specific areas range between 500 to 20 000 m3 m-2. Correlation parameters are energy dissipation criteria, related to the geometrical reactor volume and to the static liquid volume in the reactor.


2012 ◽  
Vol 45 (4) ◽  
pp. 674-678 ◽  
Author(s):  
Lukas Lomb ◽  
Jan Steinbrener ◽  
Sadia Bari ◽  
Daniel Beisel ◽  
Daniel Berndt ◽  
...  

Serial femtosecond crystallography (SFX) using X-ray free-electron laser (FEL) sources has the potential to determine the structures of macromolecules beyond the limitation of radiation damage and without the need for crystals of sufficient size for conventional crystallography. In SFX, a liquid microjet is used to inject randomly oriented crystals suspended in their storage solution into the FEL beam. Settling of crystals in the reservoir prior to the injection has been found to complicate the data collection. This article details the development of an anti-settling sample delivery instrument based on a rotating syringe pump, capable of producing flow rates and liquid pressures necessary for the operation of the injector. The device has been used successfully with crystals of different proteins, with crystal sizes smaller than 20 µm. Even after hours of continuous operation, no significant impairment of the experiments due to sample settling was observed. This article describes the working principle of the instrument and sets it in context with regard to the experimental conditions used for SFX. Hit rates for longer measuring periods are compared with and without the instrument operating. Two versions of the instrument have been developed, which both deliver sample at a constant flow rate but which differ in their minimum liquid flow rates and maximum pressures.


2008 ◽  
Vol 105 (6) ◽  
pp. 1733-1740 ◽  
Author(s):  
Santhosh T. Jayaraju ◽  
Manuel Paiva ◽  
Mark Brouns ◽  
Chris Lacor ◽  
Sylvia Verbanck

We investigated the axial dispersive effect of the upper airway structure (comprising mouth cavity, oropharynx, and trachea) on a traversing aerosol bolus. This was done by means of aerosol bolus experiments on a hollow cast of a realistic upper airway model (UAM) and three-dimensional computational fluid dynamics (CFD) simulations in the same UAM geometry. The experiments showed that 50-ml boluses injected into the UAM dispersed to boluses with a half-width ranging from 80 to 90 ml at the UAM exit, across both flow rates (250, 500 ml/s) and both flow directions (inspiration, expiration). These experimental results imply that the net half-width induced by the UAM typically was 69 ml. Comparison of experimental bolus traces with a one-dimensional Gaussian-derived analytical solution resulted in an axial dispersion coefficient of 200–250 cm2/s, depending on whether the bolus peak and its half-width or the bolus tail needed to be fully accounted for. CFD simulations agreed well with experimental results for inspiratory boluses and were compatible with an axial dispersion of 200 cm2/s. However, for expiratory boluses the CFD simulations showed a very tight bolus peak followed by an elongated tail, in sharp contrast to the expiratory bolus experiments. This indicates that CFD methods that are widely used to predict the fate of aerosols in the human upper airway, where flow is transitional, need to be critically assessed, possibly via aerosol bolus simulations. We conclude that, with all its geometric complexity, the upper airway introduces a relatively mild dispersion on a traversing aerosol bolus for normal breathing flow rates in inspiratory and expiratory flow directions.


2020 ◽  
Vol 10 (13) ◽  
pp. 4617
Author(s):  
Adel Almoslh ◽  
Falah Alobaid ◽  
Christian Heinze ◽  
Bernd Epple

The influence of pressure on the gas/liquid interfacial area is investigated in the pressure range of 0.2–0.3 MPa by using a tray column test rig. A simulated waste gas, which consisted of 30% CO2 and 70% air, was used in this study. Distilled water was employed as an absorbent. The temperature of the inlet water was 19 °C. The inlet volumetric flow rate of water was 0.17 m3/h. Two series of experiments were performed; the first series was performed at inlet gas flow rate 15 Nm3/h, whereas the second series was at 20 Nm3/h of inlet gas flow rate. The results showed that the gas/liquid interfacial area decreases when the total pressure is increased. The effect of pressure on the gas/liquid interfacial area at high inlet volumetric gas flow rates is more significant than at low inlet volumetric gas flow rates. The authors studied the effect of decreasing the interfacial area on the performance of a tray column for CO2 capture.


Author(s):  
A. Tristan Trupka ◽  
Mohammad H. Hosni ◽  
Byron W. Jones

An experimental study is performed in a mockup Boeing 767 cabin section consisting of eleven rows with seven seats per row. Carbon Dioxide (CO2) tracer gas is injected at a constant flow rate at a location of interest until concentrations in the cabin reach steady state. Ventilation equipment and flow rates representative of an actual aircraft are used for all experiments. Seats in the mockup are occupied by thermal manikins to simulate passenger heat load. A motorized beverage cart traverses the length of the cabin aisle passing by the injection location. The concentrations of tracer gas displaced by the cart are measured at locations throughout the cabin. Comparing these measurements to baseline readings taken with no cart movement, a map of the degree to which contaminant transport is affected by the beverage cart is calculated. The cabin mockup is supplied by 100% outdoor air through actual Boeing supply ductwork and linear diffusers along the cabin length above the aisles. The CO2 level is measured in the inlet air, measurement locations in the cabin, and exhaust air using nondispersive infrared (NDIR) sensors. Measured results are reported for all (54) seat locations downstream of the cart traverse/injection location for an injection location near the rear of the cabin. Analogous measurements are also conducted examining the effect of variation in cart speed and modified injection location.


1991 ◽  
Vol 35 (4) ◽  
pp. 699-699
Author(s):  
Noriyasu Mori ◽  
Hiroaki Takehara ◽  
Yoshiro Konishi ◽  
Kiyoji Nakamura

Sign in / Sign up