scholarly journals Cover Feature: Structure and activity of supported bimetallic NiPd nanoparticles: influence of preparation method on CO 2 reduction (ChemCatChem 11/2020)

ChemCatChem ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 2887-2887
Author(s):  
Adriano H. Braga ◽  
Natália J. S. Costa ◽  
Karine Philippot ◽  
Renato V. Gonçalves ◽  
János Szanyi ◽  
...  
2019 ◽  
Vol 60 (4) ◽  
pp. 432-438 ◽  
Author(s):  
M. V. Sadlivskaya ◽  
N. N. Mikheeva ◽  
V. I. Zaikovskii ◽  
G. V. Mamontov

ChemCatChem ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 2967-2976 ◽  
Author(s):  
Adriano H. Braga ◽  
Natália J. S. Costa ◽  
Karine Philippot ◽  
Renato V. Gonçalves ◽  
János Szanyi ◽  
...  

Author(s):  
R. W. Anderson ◽  
D. L. Senecal

A problem was presented to observe the packing densities of deposits of sub-micron corrosion product particles. The deposits were 5-100 mils thick and had formed on the inside surfaces of 3/8 inch diameter Zircaloy-2 heat exchanger tubes. The particles were iron oxides deposited from flowing water and consequently were only weakly bonded. Particular care was required during handling to preserve the original formations of the deposits. The specimen preparation method described below allowed direct observation of cross sections of the deposit layers by transmission electron microscopy.The specimens were short sections of the tubes (about 3 inches long) that were carefully cut from the systems. The insides of the tube sections were first coated with a thin layer of a fluid epoxy resin by dipping. This coating served to impregnate the deposit layer as well as to protect the layer if subsequent handling were required.


Author(s):  
Toshihiko Takita ◽  
Tomonori Naguro ◽  
Toshio Kameie ◽  
Akihiro Iino ◽  
Kichizo Yamamoto

Recently with the increase in advanced age population, the osteoporosis becomes the object of public attention in the field of orthopedics. The surface topography of the bone by scanning electron microscopy (SEM) is one of the most useful means to study the bone metabolism, that is considered to make clear the mechanism of the osteoporosis. Until today many specimen preparation methods for SEM have been reported. They are roughly classified into two; the anorganic preparation and the simple preparation. The former is suitable for observing mineralization, but has the demerit that the real surface of the bone can not be observed and, moreover, the samples prepared by this method are extremely fragile especially in the case of osteoporosis. On the other hand, the latter has the merit that the real information of the bone surface can be obtained, though it is difficult to recognize the functional situation of the bone.


Author(s):  
S. Tai

Extensive cytological and histological research, correlated with physiological experimental analysis, have been done on the anterior pituitaries of many different vertebrates which have provided the knowledge to create the concept that specific cell types synthesize, store and release their specific hormones. These hormones are stored in or associated with granules. Nevertheless, there are still many doubts - that need further studies, specially on the ultrastructure and physiology of these endocrine cells during the process of synthesis, transport and secretion, whereas some new methods may provide the information about the intracellular structure and activity in detail.In the present work, ultrastructural study of the hormone-secretory cells of chicken pituitaries have been done by using TEM as well as HR-SEM, to correlate the informations obtained from 2-dimensional TEM micrography with the 3-dimensional SEM topographic images, which have a continous surface with larger depth of field that - offers the adventage to interpretate some intracellular structures which were not possible to see using TEM.


1979 ◽  
Vol 42 (05) ◽  
pp. 1452-1459 ◽  
Author(s):  
Robert H Yue ◽  
Toby Starr ◽  
Menard M Gertler

SummaryCommercial porcine heparin can be separated into three distinct subtractions by using DEAE-cellulose chromatography and a stepped salt gradient. Gram quantities of heparin can be fractionated by this technique. All three heparin subtractions can accelerate the inhibition of thrombin by antithrombin III with different efficiency. The specific activities of the high activity heparin, intermediate activity heparin and low activity heparin are 228 units/mg, 142 units/mg and 95 units/mg, respectively. Both the uronic acid content and the quantity of N-SO4 for all three heparin subfractions have been evaluated. The high activity heparin has the lowest uronic acid and N-SO4 content. The successful separation of commercial heparin into three distinct subfractions by means of ion-exchange chromatography suggests that the net charge on these three heparin components will serve as a model system in the elucidation of the structure and activity relationship to the biological function of heparin.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Chuan Zhang ◽  
Jane Y. Li ◽  
John Aguada ◽  
Howard Marks

Abstract This paper introduces a novel sample preparation method using plasma focused ion-beam (pFIB) milling at low grazing angle. Efficient and high precision preparation of site-specific cross-sectional samples with minimal alternation of device parameters can be achieved with this method. It offers the capability of acquiring a range of electrical characteristic signals from specific sites on the cross-section of devices, including imaging of junctions, Fins in the FinFETs and electrical probing of interconnect metal traces.


Sign in / Sign up

Export Citation Format

Share Document