Transcatheter closure of perimembranous ventricular septal defects using amplatzer asymmetric ventricular septal defect occluder: Preliminary experience with 18-month follow up

2006 ◽  
Vol 68 (1) ◽  
pp. 145-152 ◽  
Author(s):  
Robin J. Pinto ◽  
Bharat V. Dalvi ◽  
Satyavan Sharma
2020 ◽  
Author(s):  
Long Wang ◽  
Lin Xie ◽  
Weiqiang Ruan ◽  
Tao Li ◽  
Changping Gan ◽  
...  

Abstract Background: This report presents updated data and mid-term follow-up information to a former study introducing the novel technique of percutaneous-perventricular device closure of doubly committed subarterial ventricular septal defect. Methods: Thirty-eight patients were added to the former series. There were 54 patients in total who had isolated doubly committed subarterial ventricular septal defects and underwent percutaneous-perventricular device closure. Closure outcomes and possible complications were measured in the hospital and during the 2.5-year follow-up. Results: Surgery was successful in 53 patients (98.1%). There was no death, residual shunt, new valve regurgitation or arrhythmia either perioperatively or during the entire follow-up period. Only one patient developed pericardial effusion and tamponade in the former series. The mean hospital stay was 3.2±0.6 days (range, 3.0 to 6.0 days), and only one unsuccessful case needed blood transfusion (1.9%). Conclusions: The percutaneous-perventricular device closure of isolated doubly committed subarterial ventricular septal defects appeared to be safe. Close monitoring for bleeding is essential postoperatively, especially in younger patients. This technique is generally safe with acceptable mid-term follow-up.


2019 ◽  
Vol 27 (7) ◽  
pp. 529-534
Author(s):  
Noor Mohammad Noori ◽  
Alireza Teimouri

Background Ventricular septal defect, the most common congenital heart defect, is characterized by an opening between the ventricles. This study aimed to evaluate the clinical course and associations between the characteristics of ventricular septal defect. Methods This cross-sectional study was conducted on 1498 children with ventricular septal defects, aged <19 years, who were referred to our center between 2003 and 2018. The diagnosis was suspected from a combination of clinical and laboratory findings, and confirmed by transthoracic echocardiography. Results Of the 1498 children, 54.9% were boys, 78.4% of defects were perimembranous, 30.4% of patients had pulmonary hypertension, 67.5% had regular follow-up, and 76 (5.1%) had complications including 28 (1.9%) with Eisenmenger syndrome; 10 died due to Eisenmenger syndrome during follow-up. The defects closed spontaneously in 38.9% and after surgery in 20.9%. Boys tended to have more perimembranous, inlet, and outlet forms (56.40%, 50.60%, 51.90%, respectively), whereas girls had more muscular types (51.80%). Most patients with pulmonary hypertension had perimembranous defects (83.10%). The majority of patients with pulmonary hypertension had large (63.40%) or moderate (36.60%) defects. Pulmonary hypertension had a significant association with defect size ( p < 0.001). After surgery, residual defects were found mostly in cases of large defects (84.60%). Most patients with spontaneous closure were younger than 4 years. Conclusion Almost four-fifths of children with ventricular septal defects had perimembranous types, and almost one-third had pulmonary hypertension which was associated with defect size. Two-fifths of the defects closed spontaneously. There was a low incidence of complications after surgery.


2018 ◽  
Vol 28 (4) ◽  
pp. 598-601 ◽  
Author(s):  
Sezen Atik-Ugan ◽  
Irfan Levent Saltik

AbstractPatent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.


2020 ◽  
Vol 30 (10) ◽  
pp. 1517-1520
Author(s):  
Raymond N. Haddad ◽  
Régis Gaudin ◽  
Damien Bonnet ◽  
Sophie Malekzadeh-Milani

AbstractThe hybrid perventricular approach for the closure of trabecular ventricular septal defects is an attractive treatment modality for small children. Worldwide experience has shown that procedure success is influenced by the defect anatomical accessibility, operators’ expertise, and device technical features. In May 2018, a new promising device, the KONAR-Multi-functional™ ventricular septal defect occluder (Lifetech, Shenzhen, China), obtained CE-marking for septal defect transcatheter closure after the first-in-man implantation in 2013. Herein, this is the first report of successful perventricular closure of ventricular septal defect using this new device in a child with significant co-morbidities.


2020 ◽  
Author(s):  
Long Wang ◽  
Lin Xie ◽  
Weiqiang Ruan ◽  
Tao Li ◽  
Changping Gan ◽  
...  

Abstract Background: This report presents updated data and mid-term follow-up information to a former study introducing the novel technique of percutaneous-perventricular device closure of doubly committed subarterial ventricular septal defect. Methods: Thirty-eight patients were added to the former series. There were 54 patients in total who had isolated doubly committed subarterial ventricular septal defects and underwent percutaneous-perventricular device closure. Closure outcomes and possible complications were measured in the hospital and during the 2.5-year follow-up. Results: Surgery was successful in 53 patients (98.1%). There was no death, residual shunt, new valve regurgitation or arrhythmia either perioperatively or during the entire follow-up period. Only one patient developed pericardial effusion and tamponade in the former series. The mean hospital stay was 3.2±0.6 days (range, 3.0 to 6.0 days), and only one unsuccessful case needed blood transfusion (1.9%). Conclusions: The percutaneous-perventricular device closure of isolated doubly committed subarterial ventricular septal defects appeared to be safe. Close monitoring for bleeding is essential postoperatively, especially in younger patients. This technique is generally safe with acceptable mid-term follow-up.


2017 ◽  
Vol 27 (7) ◽  
pp. 1437-1440
Author(s):  
Bhavik Champaneri ◽  
Mahesh Kappanayil ◽  
Raman K. Kumar

AbstractCatheter closure of membranous ventricular septal defects is generally not considered feasible in small infants. We report the successful closure of a membranous ventricular septal defect in a 1.8-kg infant with bilateral femoral artery occlusion using Amplatzer Duct Occluder II additional size device. The ventricular septal defect was crossed from the right ventricle, and the device was deployed using transthoracic echocardiographic guidance.


PEDIATRICS ◽  
1979 ◽  
Vol 63 (2) ◽  
pp. 204-206
Author(s):  
Bruce S. Alpert ◽  
David H. Cook ◽  
P. Jacob Varghese ◽  
Richard D. Rowe

The natural history of small ventricular septal defect (VSD) was studied in 50 infants for up to 10.5 years. The VSD closed spontaneously in 34 patients. Life-table analysis of the data showed that by 10 years of age, 75% of small VSD will close spontaneously; the figure is higher for defects in the muscular septum (83%).


Sign in / Sign up

Export Citation Format

Share Document