Preliminary results utilizing a new percutaneous transluminal coronary angioplasty balloon catheter

1990 ◽  
Vol 20 (2) ◽  
pp. 108-113 ◽  
Author(s):  
J. David Talley ◽  
Abraham Joseph ◽  
Joel Kupersmith
2000 ◽  
Vol 10 (6) ◽  
pp. 641-643 ◽  
Author(s):  
M. O. Galal ◽  
K. Attas ◽  
G. Baslaim

AbstractAn infant developed severe desaturation within a few hours of construction of a modified Blalock-Taussig shunt. Echocardiography revealed that the shunt had become occluded, and this was confirmed angiographically. At catheterisation, therefore, we passed a 0.014”percutaneous transluminal coronary angioplasty wire through the occluded shunt into the right pulmonary artery and then dilated the shunt successfully using a 5 mm coronary angioplasty balloon. Six weeks later, the shunt remained patent.


Sign in / Sign up