Pulmonary venous pressure: Relationship to pulmonary artery, pulmonary wedge, and left atrial pressure in normal, lightly sedated dogs

2002 ◽  
Vol 56 (3) ◽  
pp. 432-438 ◽  
Author(s):  
Hari P. Chaliki ◽  
David G. Hurrell ◽  
Rick A. Nishimura ◽  
Rebekah A. Reinke ◽  
Christopher P. Appleton
1991 ◽  
Vol 71 (1) ◽  
pp. 314-316 ◽  
Author(s):  
S. J. Allen ◽  
R. E. Drake ◽  
G. A. Laine ◽  
J. C. Gabel

Positive end-expiratory pressure (PEEP) increases central venous pressure, which in turn impedes return of systemic and pulmonary lymph, thereby favoring formation of pulmonary edema with increased microvascular pressure. In these experiments we examined the effect of thoracic duct drainage on pulmonary edema and hydrothorax associated with PEEP and increased left atrial pressure in unanesthetized sheep. The sheep were connected via a tracheostomy to a ventilator that supplied 20 Torr PEEP. By inflation of a previously inserted intracardiac balloon, left atrial pressure was increased to 35 mmHg for 3 h. Pulmonary arterial, systemic arterial, and central venous pressure as well as thoracic duct lymph flow rate were continuously monitored, and the findings were compared with those in sheep without thoracic duct cannulation (controls). At the end of the experiment we determined the severity of pulmonary edema and the volume of pleural effusion. With PEEP and left atrial balloon insufflation, central venous and pulmonary arterial pressure were increased approximately threefold (P less than 0.05). In sheep with a thoracic duct fistula, pulmonary edema was less (extra-vascular fluid-to-blood-free dry weight ratio 4.8 +/- 1.0 vs. 6.1 +/- 1.0; P less than 0.05), and the volume of pleural effusion was reduced (2.0 +/- 2.9 vs. 11.3 +/- 9.6 ml; P less than 0.05). Our data signify that, in the presence of increased pulmonary microvascular pressure and PEEP, thoracic duct drainage reduces pulmonary edema and hydrothorax.


1991 ◽  
Vol 19 (3) ◽  
pp. 399-404
Author(s):  
REINHOLD FRETSCHNER ◽  
THOMAS KLÖSS ◽  
HEINZ GUGGENBERGER ◽  
DIETER HEUSER ◽  
HANS-JÖRG SCHMID

2009 ◽  
Vol 106 (2) ◽  
pp. 651-661 ◽  
Author(s):  
Da Xu ◽  
N. Bari Olivier ◽  
Ramakrishna Mukkamala

We developed a technique to continuously (i.e., automatically) monitor cardiac output (CO) and left atrial pressure (LAP) by mathematical analysis of the pulmonary artery pressure (PAP) waveform. The technique is unique to the few previous related techniques in that it jointly estimates the two hemodynamic variables and analyzes the PAP waveform over time scales greater than a cardiac cycle wherein wave reflections and inertial effects cease to be major factors. First, a 6-min PAP waveform segment is analyzed so as to determine the pure exponential decay and equilibrium pressure that would eventually result if cardiac activity suddenly ceased (i.e., after the confounding wave reflections and inertial effects vanish). Then, the time constant of this exponential decay is computed and assumed to be proportional to the average pulmonary arterial resistance according to a Windkessel model, while the equilibrium pressure is regarded as average LAP. Finally, average proportional CO is determined similar to invoking Ohm's law and readily calibrated with one thermodilution measurement. To evaluate the technique, we performed experiments in five dogs in which the PAP waveform and accurate, but highly invasive, aortic flow probe CO and LAP catheter measurements were simultaneously recorded during common hemodynamic interventions. Our results showed overall calibrated CO and absolute LAP root-mean-squared errors of 15.2% and 1.7 mmHg, respectively. For comparison, the root-mean-squared error of classic end-diastolic PAP estimates of LAP was 4.7 mmHg. On future successful human testing, the technique may potentially be employed for continuous hemodynamic monitoring in critically ill patients with pulmonary artery catheters.