Simultaneous determination of thirteen substances related to NAFLD in mouse brain tissue using 3‐aminobutyric acid as internal standard by HPLC–FLD

2020 ◽  
Vol 34 (3) ◽  
Author(s):  
Yong‐hong Liu ◽  
Ting‐ting Du ◽  
Jing‐yuan Wan ◽  
Hua Zhao ◽  
Dan Huang ◽  
...  
2017 ◽  
Vol 1068-1069 ◽  
pp. 64-70 ◽  
Author(s):  
Christine A. Farthing ◽  
Don E. Farthing ◽  
Ronald E. Gress ◽  
Douglas H. Sweet

Author(s):  
Hina Shamshad ◽  
Ali Sayqal ◽  
Jahan Zeb ◽  
Agha Zeeshan Mirza

Abstract A simple, accurate and precise RP-HPLC method was developed for the simultaneous determination of chloroquine, pyrimethamine and cetirizine hydrochloride concentrations in bulk drug and human serum. The assay was performed using a mobile phase of methanol: water (70:30) at pH of 2.8 ± 0.05 on the Purospher C-18 column with UV detection at 230 nm and rosuvastatin used as an internal standard. The retention times observed for chloroquine, pyrimethamine and cetirizine hydrochloride were 3.5, 2.5 and 5.5 minutes, respectively. The method was found to be specific for the assayed drugs showing a linear response in the concentration range of 1–100 μg mL−1 with coefficients of determination values of (r = 0.999). The method was developed and validated according to ICH guidelines. The method was used to monitor the serum samples and was found to be sensitive for therapeutic purposes, showing the potential to be a useful tool for routine analysis in laboratories.


Author(s):  
Sushil D. Patil ◽  
Pravin B. Shelke ◽  
Priti Aher ◽  
Maswood Ahmed Hafizur Rahman

A simple, rapid, economic, sensitive and precise HPLC method has been developed for the simultaneous determination of Sulphadoxine and Pyrimethamine in pharmaceutical dosage form by taking Tolterodine as an internal standard. The method was carried out using Phenomenex C18 (4.6ID × 250mm; 5µm) column and mobile phase comprised of methanol and Phosphate Buffer in proportion of ratio 60:40 v/v. The flow rate was 1.0mL/min and detection was carried out at 276nm. The retention time of Sulphadoxine, Pyrimethamine and Tolterodine were found to be 2.967, 4.058 and 6.908 respectively. Linearity of Sulphadoxine and Pyrimethamine in the range of 2 to 12μg/mL and 4 to 24μg/mL respectively. The % recoveries of Sulphadoxine and Pyrimethamine were found to be in between 99.93% to 99. 96 % respectively. The proposed method is suitable for the routine quality control analysis for simultaneous determination of Sulphadoxine and Pyrimethamine was in bulk and pharmaceutical dosage form.


Molecules ◽  
2020 ◽  
Vol 25 (11) ◽  
pp. 2509
Author(s):  
Antonella Aresta ◽  
Gualtiero Milani ◽  
Maria Lisa Clodoveo ◽  
Carlo Franchini ◽  
Pietro Cotugno ◽  
...  

The absence of vitamin E from the diet can lead to cardiovascular disease, cancer, cataracts, and premature aging. Vitamin K deficiency can lead to bleeding disorders. These fat-soluble vitamins are important nutritional factors that can be determined in different methods in vegetables. In this work, the simultaneous determination of α-tocopherol, α-tocopheryl acetate, phylloquinone, and menaquinone-4 by gas chromatography–mass spectrometry (GC–MS) has been optimized using both direct injection and solid phase microextraction (SPME). Three different sample pre-treatment approaches based on: (A) solid–liquid–liquid–liquid extraction (SLE–LLE), (B) SLE, and (C) SPME were then applied to extract the target analytes from vegetables samples using menaquinone as internal standard. All the procedures allowed the determination of the target analytes in onion, carrot, celery, and curly kale samples. Similar results were obtained with the three different approaches, even if the one based on SPME offers the best performance, together with a reduced use of solvent, time consumption, and experimental complexity, which makes it the preferable option for industrial applications.


Sign in / Sign up

Export Citation Format

Share Document