A porphyrin-based fluorescence method for zinc determination in commercial propolis extracts without sample pretreatment

Luminescence ◽  
2017 ◽  
Vol 32 (7) ◽  
pp. 1227-1232 ◽  
Author(s):  
Gastón Darío Pierini ◽  
Victor Hugo A. Pinto ◽  
Clarissa G.C. Maia ◽  
Wallace D. Fragoso ◽  
Julio S. Reboucas ◽  
...  
2020 ◽  
Vol 86 (10) ◽  
pp. 18-22
Author(s):  
K. N. Vdovin ◽  
K. G. Pivovarova ◽  
N. A. Feoktistov ◽  
T. B. Ponamareva

Zinc sulfate is the main component in the composition of the acidic zinc plating electrolyte. Deviation in the electrolyte composition from the optimum content leads to destabilization of the electrolysis process and deteriorate the quality of the resulting zinc coating. The proper quality of a zinc coating obtained by galvanic deposition can be ensured only with timely monitoring and adjustment of the electrolyte composition. A technique of X-ray fluorescence determination of zinc (in terms of zinc sulfate) in an acidic zinc plating electrolyte is proposed. The study was carried out using an ARL Quant’X energy dispersive spectrometer (Thermo Fisher Scientific, USA) with a semiconductor silicon-lithium detector. The features of the spectrometer design are presented. The optimal parameters of excitation and detection of zinc radiation were specified when the electrolyte sample was diluted 1:1000. The ZnKα1 line was used as an analytical line. The plotted calibration graph is linear, the correlation coefficient being 0.999234. The results of zinc determination according to the developed method were compared with the data of the reference method of complexometric titration to prove the reliability of the procedure. The results are characterized by good convergence and accuracy. The proposed method of X-ray fluorescence zinc determination in a zinc plating electrolyte equals complexometric titration in the limiting capabilities and even exceeds the latter in terms of the simplicity of sample preparation and rapidity. The developed method of X-ray fluorescence determination of zinc is implemented in analysis of the electrolyte used in the continuous galvanizing unit at «METSERVIS LLC».


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Anita G. Amin ◽  
Prithwiraj De ◽  
Barbara Graham ◽  
Roger I. Calderon ◽  
Molly F. Franke ◽  
...  

AbstractOur study sought to determine whether urine lipoarabinomannan (LAM) could be validated in a sample cohort that consisted mainly of HIV uninfected individuals that presented with tuberculosis symptoms. We evaluated two tests developed in our laboratory, and used them on clinical samples from Lima, Peru where incidence of HIV is low. ELISA analysis was performed on 160 samples (from 140 adult culture-confirmed TB cases and 20 symptomatic TB-negative child controls) using 100 μL of urine after pretreatment with Proteinase K. Two different mouse monoclonal antibodies-CS35 and CHCS9-08 were used individually for capture of urine LAM. Among cases, optical density (OD450) values had a positive association with higher bacillary loads. The 20 controls had negative values (below the limit of detection). The assay correctly identified all samples (97–100% accuracy confidence interval). For an alternate validation of the ELISA results, we analyzed all 160 urine samples using an antibody independent chemoanalytical approach. Samples were called positive only when LAM surrogates—tuberculostearic acid (TBSA) and d-arabinose (d-ara)—were found to be present in similar amounts. All TB cases, including the 40 with a negative sputum smear had LAM in detectable quantities in urine. None of the controls had detectable amounts of LAM. Our study shows that urinary LAM detection is feasible in HIV uninfected, smear negative TB patients.


Sign in / Sign up

Export Citation Format

Share Document