Achieving a low human dose for targeted covalent drugs: Pharmacokinetic and pharmacodynamic considerations on target characteristics and drug attributes

Author(s):  
Zheng Yang
2020 ◽  
Vol 8 (Suppl 3) ◽  
pp. A303-A303
Author(s):  
George Blumenschein ◽  
Siddhartha Devarakonda ◽  
Melissa Johnson ◽  
Victor Moreno ◽  
Justin Gainor ◽  
...  

BackgroundADP-A2M10 SPEAR T-cells are genetically engineered autologous T-cells that express a high affinity MAGE-A10-specific T-cell receptor targeting MAGE-A10+tumors in the context of HLA-A*02. This trial is now complete (NCT02592577).MethodsThis first-in-human dose escalation trial utilized a modified 3+3 design to evaluate safety and antitumor activity. Eligible patients (pts) were HLA-A*02+ with advanced non-small cell lung cancer (NSCLC) expressing MAGE-A10. Pts underwent apheresis; T-cells were isolated, transduced with a lentiviral vector containing the TCR targeting MAGE-A10, and expanded. Pts underwent lymphodepletion (LD) with varying doses/schedules of fludarabine (Flu) and cyclophosphamide (Cy) prior to receiving ADP-A2M10. ADP-A2M10 was administered at Dose Level (DL) 1= 0.1×109, DL2 0.5–1.2×109, and DL3/Expansion= 1.2–15×109 transduced cells.ResultsAs of Jan 10, 2020, 11 pts (6 male/5 female) with NSCLC (3 squamous cell, 7 adenocarcinoma, 1 adenosquamous) were treated. Five, 3 and 3 pts received cells at DL1, DL2, and DL3/Expansion, respectively. The most frequently reported adverse events ≥ Grade 3 were lymphopenia (11), leukopenia (9), neutropenia (8), anemia (6), thrombocytopenia (5), and hyponatremia (5). Three pts reported CRS (Grades 1, 2, and 4, respectively). One pt received the highest dose of LD (Flu 30 mg/m2 Day 1 4 and Cy 1800 mg/m2 Day 1–2) prior to a second infusion and had a partial response (PR). This pt subsequently developed aplastic anemia and died. Responses included: 1 pt – PR, 3 pts - stable disease, 2 pts – progressive disease, 1 pt - too early to determine, 4 pts - off-study prior to tumor assessment. SPEAR T-cells were detectable in peripheral blood from pts at each dose level, and in tumor tissue from pts at DL1 and DL3.ConclusionsADP-A2M10 SPEAR T-cells have shown acceptable safety and no evidence of toxicity related to off-target binding or alloreactivity. Given the minimal antitumor activity and the discovery that MAGE-A10 expression frequently overlaps with MAGE-A4 expression, the clinical program has closed. Several trials with SPEAR T-cells targeting MAGE-A4 are ongoing (https://bit.ly/35htsZK).Trial RegistrationNCT02592577Ethics ApprovalThe trial was conducted in accordance with the principles of the Declaration of Helsinki and the International Conference on Harmonization Good Clinical Practice guidelines and was approved by local authorities. An independent ethics committee or institutional review board approved the clinical protocol at each participating center. All the patients provided written informed consent before study entry.


2021 ◽  
pp. 109158182098607
Author(s):  
Narendra S. Deshmukh ◽  
Shailesh Gumaste ◽  
Silma Subah ◽  
Nathasha Omal Bogoda

Palmitoylethanolamide (PEA) is an endogenous ethanolamine playing a protective and homeodynamic role in animals and plants. Prenatal developmental toxicity of PEA was tested following oral administration to pregnant female Wistar rats, from days 0 to 19 of gestation, at dosage of 250, 500, or 1,000 mg/kg body weight, according to Organisation for Economic Co-operation and Development Test Guideline No. 414. On gestation day 20, cesarean sections were performed on the dams, followed by examination of their ovaries and uterine contents. The fetuses were further examined for external, visceral, and skeletal abnormalities. Palmitoylethanolamide did not cause any alterations at any of the given dosages in the measured maternal parameters of systemic toxicity (body weight, food consumption, survival, thyroid functions, organ weight, histopathology), reproductive toxicity (preimplantation and postimplantation losses, uterus weight, number of live/dead implants and early/late resorptions, litter size and weights, number of fetuses, their sex ratio), and fetal external, visceral, or skeletal observations. Any alterations that were recorded were “normal variations” or “minor anomalies,” which were unrelated to treatment with PEA. Under the condition of this prenatal study, the no-observed-adverse-effect level of PEA for maternal toxicity, embryotoxicity, fetotoxicity, and teratogenicity in rats was found to be >1,000 mg/kg body weight/d. It indicates that PEA is well tolerated by and is safe to pregnant rats even at a high dose of 1,000 mg/kg body weight/d, equivalent to a human dose of greater than 9.7 g/d. This prenatal developmental toxicity study contributes greatly in building a robust safety profile for PEA.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4365
Author(s):  
Kwangyong Jung ◽  
Jae-In Lee ◽  
Nammoon Kim ◽  
Sunjin Oh ◽  
Dong-Wook Seo

Radar target classification is an important task in the missile defense system. State-of-the-art studies using micro-doppler frequency have been conducted to classify the space object targets. However, existing studies rely highly on feature extraction methods. Therefore, the generalization performance of the classifier is limited and there is room for improvement. Recently, to improve the classification performance, the popular approaches are to build a convolutional neural network (CNN) architecture with the help of transfer learning and use the generative adversarial network (GAN) to increase the training datasets. However, these methods still have drawbacks. First, they use only one feature to train the network. Therefore, the existing methods cannot guarantee that the classifier learns more robust target characteristics. Second, it is difficult to obtain large amounts of data that accurately mimic real-world target features by performing data augmentation via GAN instead of simulation. To mitigate the above problem, we propose a transfer learning-based parallel network with the spectrogram and the cadence velocity diagram (CVD) as the inputs. In addition, we obtain an EM simulation-based dataset. The radar-received signal is simulated according to a variety of dynamics using the concept of shooting and bouncing rays with relative aspect angles rather than the scattering center reconstruction method. Our proposed model is evaluated on our generated dataset. The proposed method achieved about 0.01 to 0.39% higher accuracy than the pre-trained networks with a single input feature.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Irina Kapitanova ◽  
Sharmi Biswas ◽  
Sabrina Divekar ◽  
Eric J. Kemmerer ◽  
Robert A. Rostock ◽  
...  

Abstract Background Brachial plexopathy is a potentially serious complication from stereotactic body radiation therapy (SBRT) that has not been widely studied. Therefore, we compared datasets from two different institutions and generated a brachial plexus dose–response model, to quantify what dose constraints would be needed to minimize the effect on normal tissue while still enabling potent therapy for the tumor. Methods Two published SBRT datasets were pooled and modeled from patients at Indiana University and the Richard L. Roudebush Veterans Administration Medical Center from 1998 to 2007, as well as the Karolinska Institute from 2008 to 2013. All patients in both studies were treated with SBRT for apically located lung tumors localized superior to the aortic arch. Toxicities were graded according to Common Terminology Criteria for Adverse Events, and a probit dose response model was created with maximum likelihood parameter fitting. Results This analysis includes a total of 89 brachial plexus maximum point dose (Dmax) values from both institutions. Among the 14 patients who developed brachial plexopathy, the most common complications were grade 2, comprising 7 patients. The median follow-up was 30 months (range 6.1–72.2) in the Karolinska dataset, and the Indiana dataset had a median of 13 months (range 1–71). Both studies had a median range of 3 fractions, but in the Indiana dataset, 9 patients were treated in 4 fractions, and the paper did not differentiate between the two, so our analysis is considered to be in 3–4 fractions, one of the main limitations. The probit model showed that the risk of brachial plexopathy with Dmax of 26 Gy in 3–4 fractions is 10%, and 50% with Dmax of 70 Gy in 3–4 fractions. Conclusions This analysis is only a preliminary result because more details are needed as well as additional comprehensive datasets from a much broader cross-section of clinical practices. When more institutions join the QUANTEC and HyTEC methodology of reporting sufficient details to enable data pooling, our field will finally reach an improved understanding of human dose tolerance.


2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Heather C. M. Allaway ◽  
Roger A. Pierson ◽  
Jesse Invik ◽  
Susan A. Bloomfield

Abstract Background Long-acting, reversible contraceptives (LARC; progestin only) are an increasingly common hormonal contraceptive choice in reproductive aged women looking to suppress ovarian function and menstrual cyclicity. The overall objective was to develop and validate a rodent model of implanted etonogestrel (ENG) LARC, at body size equivalent doses to the average dose received by women during each of the first 3 years of ENG subdermal rod LARC use. Methods Intact, virgin, female Sprague-Dawley rats (16-wk-old) were randomized to 1 of 4 groups (n = 8/group) of ENG LARC (high-0.30μg/d, medium-0.17μg/d, low-0.09μg/d, placebo-0.00μg/d) via a slow-release pellet implanted subcutaneously. Animals were monitored for 21 days before and 29 days following pellet implantation using vaginal smears, ultrasound biomicroscopy (UBM), saphenous blood draws, food consumption, and body weights. Data were analyzed by chi-square, non-parametric, univariate, and repeated measures 2-way ANOVA. Results Prior to pellet implantation there was no difference in time spent in estrus cycle phases among the treatment groups (p > 0.30). Following pellet implantation there was a dose-dependent impact on the time spent in diestrus and estrus (p < 0.05), with the high dose group spending more days in diestrus and fewer days in estrus. Prior to pellet insertion there was not an association between treatment group and estrus cycle classification (p = 0.57) but following pellet implantation there was a dose-dependent association with cycle classification (p < 0.02). Measurements from the UBM (ovarian volume, follicle count, corpora lutea count) indicate an alteration of ovarian function following pellet implantation. Conclusion Assessment of estrus cyclicity indicated a dose-response relationship in the shift to a larger number of acyclic rats and longer in duration spent in the diestrus phase. Therefore, each dose in this model mimics some of the changes observed in the ovaries of women using ENG LARC and provides an opportunity for investigating the impacts on non-reproductive tissues in the future.


Vaccines ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 535
Author(s):  
Ban Qi Tay ◽  
Quentin Wright ◽  
Rahul Ladwa ◽  
Christopher Perry ◽  
Graham Leggatt ◽  
...  

The development of cancer vaccines has been intensively pursued over the past 50 years with modest success. However, recent advancements in the fields of genetics, molecular biology, biochemistry, and immunology have renewed interest in these immunotherapies and allowed the development of promising cancer vaccine candidates. Numerous clinical trials testing the response evoked by tumour antigens, differing in origin and nature, have shed light on the desirable target characteristics capable of inducing strong tumour-specific non-toxic responses with increased potential to bring clinical benefit to patients. Novel delivery methods, ranging from a patient’s autologous dendritic cells to liposome nanoparticles, have exponentially increased the abundance and exposure of the antigenic payloads. Furthermore, growing knowledge of the mechanisms by which tumours evade the immune response has led to new approaches to reverse these roadblocks and to re-invigorate previously suppressed anti-tumour surveillance. The use of new drugs in combination with antigen-based therapies is highly targeted and may represent the future of cancer vaccines. In this review, we address the main antigens and delivery methods used to develop cancer vaccines, their clinical outcomes, and the new directions that the vaccine immunotherapy field is taking.


2017 ◽  
Vol 60 (13) ◽  
pp. 5933-5939 ◽  
Author(s):  
Timothy B. Durham ◽  
Jothirajah Marimuthu ◽  
James L. Toth ◽  
Chin Liu ◽  
Lisa Adams ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document