Photoreactive and Metal-Platable Copolymer Inks for High-Throughput, Room-Temperature Printing of Flexible Metal Electrodes for Thin-Film Electronics

2016 ◽  
Vol 28 (24) ◽  
pp. 4926-4934 ◽  
Author(s):  
You Yu ◽  
Xiang Xiao ◽  
Yaokang Zhang ◽  
Kan Li ◽  
Casey Yan ◽  
...  
2018 ◽  
Vol 30 (29) ◽  
pp. 1801852 ◽  
Author(s):  
Mahmoud Tavakoli ◽  
Mohammad H. Malakooti ◽  
Hugo Paisana ◽  
Yunsik Ohm ◽  
Daniel Green Marques ◽  
...  

2017 ◽  
Vol 5 (15) ◽  
pp. 3725-3735 ◽  
Author(s):  
Giorgio Nava ◽  
Francesco Fumagalli ◽  
Salvatore Gambino ◽  
Isabella Farella ◽  
Giorgio Dell'Erba ◽  
...  

High-throughput plasma synthesis of highly crystalline nanoparticle-assembled silicon thin films.


2018 ◽  
Vol 30 (29) ◽  
pp. 1870215 ◽  
Author(s):  
Mahmoud Tavakoli ◽  
Mohammad H. Malakooti ◽  
Hugo Paisana ◽  
Yunsik Ohm ◽  
Daniel Green Marques ◽  
...  

Author(s):  
R. C. Moretz ◽  
G. G. Hausner ◽  
D. F. Parsons

Use of the electron microscope to examine wet objects is possible due to the small mass thickness of the equilibrium pressure of water vapor at room temperature. Previous attempts to examine hydrated biological objects and water itself used a chamber consisting of two small apertures sealed by two thin films. Extensive work in our laboratory showed that such films have an 80% failure rate when wet. Using the principle of differential pumping of the microscope column, we can use open apertures in place of thin film windows.Fig. 1 shows the modified Siemens la specimen chamber with the connections to the water supply and the auxiliary pumping station. A mechanical pump is connected to the vapor supply via a 100μ aperture to maintain steady-state conditions.


Author(s):  
E. L. Vigil ◽  
E. F. Erbe

In cotton seeds the radicle has 12% moisture content which makes it possible to prepare freeze-fracture replicas without fixation or cryoprotection. For this study we have examined replicas of unfixed radicle tissue fractured at room temperature to obtain data on organelle and membrane structure.Excised radicles from seeds of cotton (Gossyplum hirsutum L. M-8) were fractured at room temperature along the longitudinal axis. The fracture was initiated by spliting the basal end of the excised radicle with a razor. This procedure produced a fracture through the tissue along an unknown fracture plane. The warm fractured radicle halves were placed on a thin film of 100% glycerol on a flat brass cap with fracture surface up. The cap was rapidly plunged into liquid nitrogen and transferred to a freeze- etch unit. The sample was etched for 3 min at -95°C to remove any condensed water vapor and then cooled to -150°C for platinum/carbon evaporation.


Author(s):  
Alfred Ludwig ◽  
Mona Nowak ◽  
Swati Kumari ◽  
Helge S. Stein ◽  
Ramona Gutkowski ◽  
...  

Optik ◽  
2021 ◽  
Vol 234 ◽  
pp. 166615
Author(s):  
S.R. Cynthia ◽  
R. Sivakumar ◽  
C. Sanjeeviraja

Author(s):  
Kumar Haunsbhavi ◽  
Karuppiah Deva Arun Kumar ◽  
Paolo Mele ◽  
Omar M. Aldossary ◽  
Mohd Ubaidullah ◽  
...  

2021 ◽  
Vol 13 (2) ◽  
pp. 3445-3453
Author(s):  
Wei Huang ◽  
Xinge Yu ◽  
Li Zeng ◽  
Binghao Wang ◽  
Atsuro Takai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document