Acrylic Resins

2017 ◽  
pp. 115-124
Keyword(s):  
Author(s):  
Liza B. Martinez ◽  
Susan M. Wick

Rapid freezing and freeze-substitution have been employed as alternatives to chemical fixation because of the improved structural preservation obtained in various cell types. This has been attributed to biomolecular immobilization derived from the extremely rapid arrest of cell function. These methods allow the elimination of conventionally used fixatives, which may have denaturing or “masking” effects on proteins. Thus, this makes them ideal techniques for immunocytochemistry, in which preservation of both ultrastructure and antigenicity are important. These procedures are also compatible with cold embedding acrylic resins which are known to increase sensitivity in immunolabelling.This study reveals how rapid freezing and freeze-substitution may prove to be useful in the study of the mobile allergenic proteins of rye grass and ragweed. Most studies have relied on the use of osmium tetroxide to achieve the necessary ultrastructural detail in pollen whereas those that omitted it have had to contend with poor overall preservation.


2019 ◽  
Vol 14 (1) ◽  
pp. 110
Author(s):  
Assiss. Prof. Dr. Sabiha Mahdi Mahdi ◽  
Dr. Firas Abd K. Abd K.

Aim: The aimed study was to evaluate the influence of silver nitrate on surfacehardness and tensile strength of acrylic resins.Materials and methods: A total of 60 specimens were made from heat polymerizingresins. Two mechanical tests were utilized (surface hardness and tensile strength)and 4 experimental groups according to the concentration of silver nitrate used.The specimens without the use of silver nitrate were considered as control. Fortensile strength, all specimens were subjected to force till fracture. For surfacehardness, the specimens were tested via a durometer hardness tester. Allspecimens data were analyzed via ANOVA and Tukey tests.Results: The addition of silver nitrate to acrylic resins reduced significantly thetensile strength. Statistically, highly significant differences were found among allgroups (P≤0.001). Also, the difference between control and experimental groupswas highly significant (P≤0.001). For surface hardness, the silver nitrate improvedthe surface hardness of acrylics. Highly significant differences were statisticallyobserved between control and 900 ppm group (P≤0.001); and among all groups(P≤0.001)with exception that no significant differences between control and150ppm; and between 150ppm and 900ppm groups(P>0.05).Conclusion: The addition of silver nitrate to acrylics reduced significantly the tensilestrength and improved slightly the surface hardness.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2014 ◽  
Vol 1025-1026 ◽  
pp. 797-802 ◽  
Author(s):  
Tassanaporn Saen-Isara ◽  
Surachai Dechkunakorn ◽  
Niwat Anuwongnukroh ◽  
Toemsak Srikhirin ◽  
Siriporn Tanodekaew

Objective: To evaluate the effects of interchanging the liquid components of two commercially available orthodontic auto-polymerizing acrylic resin in their flexural properties, clarity and setting time


2015 ◽  
Vol 44 (5) ◽  
pp. 262-267 ◽  
Author(s):  
José Vitor Quinelli Mazaro ◽  
Luiz Miguel Minani ◽  
Adriana Cristina Zavanelli ◽  
Caroline Cantieri de Mello ◽  
Cleidiel Aparecido Araújo Lemos

AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001).ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


2011 ◽  
Vol 40 (3) ◽  
pp. 125-132 ◽  
Author(s):  
A Dashtizadeh ◽  
M Abdouss ◽  
M Khorassani ◽  
H Mahdavi ◽  
M Mohammadi Aslzadeh ◽  
...  

2016 ◽  
Vol 24 (12) ◽  
pp. 13687 ◽  
Author(s):  
Lijia Jiang ◽  
Wei Xiong ◽  
Yushen Zhou ◽  
Ying Liu ◽  
Xi Huang ◽  
...  

Author(s):  
Saeed Noorollahian ◽  
Farinaz Shirban ◽  
Vahid Mojiri

Introduction: The daily use of orthodontic removable plates can interfere with the self-cleansing function of the mouth. Although various techniques have been proposed for cleaning removable orthodontic appliances, there is no consensus on the use of a safe method that preserves the physical properties of the appliance. This study aimed to investigate the effect of using hydrochloric acid (10%, for removal of mineral deposits) and sodium hypochlorite (5.25%, to remove organic matter and discolorations) on surface hardness and roughness of self-cure orthodontic acrylic resins. Materials & Methods: This cross-sectional laboratory study was conducted in the fall of 2017 at Isfahan University of Medical science and Isfahan University of Technology. In this study two orthodontic acrylic resins (Orthocryl® and Acropars®) were used. Eighty samples (12×10×3 mm) from each one were fabricated and divided into four groups (n = 20). Group 1: 15 minutes immersion in household cleaner liquid (Hydrochloric acid, 10%) followed by15 minutes immersion in household bleach liquid (Sodium Hypochlorite, 5.25%). In group 2, immersions were repeated just like group two times and in group 3, were done three times. Group 4 was as control and had no immersion. The surface hardness and roughness of samples were measured. Data were analyzed with Two Way ANOVA and the significance level was set at 0.05. Results: The number of immersion procedures did not significantly affect the surface hardness (p value = 0.958) and surface roughness (p value = 0.657) in the different study groups. There was no significant difference in the surface hardness between the two acrylic resin brands (p value = 0.077); however, Acropars acrylic resin samples exhibited significantly higher surface roughness compared to the Orthocryl acrylic resin samples(p value < 0.001). Conclusion: 15 minutes of immersion in 10% HCl, followed by 15 minutes of immersion in 5.25% NaOCl and repetition of the procedure three times did not significantly affect the surface hardness and roughness of self-cured acrylic resins.


Sign in / Sign up

Export Citation Format

Share Document