The Separation of Organic Vapors from Gas Streams by Means of Membranes

2003 ◽  
pp. 69-94 ◽  
Author(s):  
K. Ohlrogge ◽  
K. Stürken
Keyword(s):  
Author(s):  
Virgil Peck ◽  
W. L. Carter

Any electron microscopical study of the morphology of bulk polymers has throughout the years been hampered by the lack of any real ability to produce meaningful surface variations for replication. True etching of polymers should show crystalline and amorphous regions in some form of relief. The use of solvents, acids, organic vapors, and inert ion bombardment to etch samples has proved to be useful only in limited applications. Certainly many interpretations of these results are subject to question.The recent use of a radiofrequency (R. F.) plasma of oxygen to degrade and remove organic material with only minor heating has opened a new possibility for etching polymers. However, rigid control of oxygen flow, time, current, and sample position are necessary in order to obtain reproducible results. The action is confined to surface layers; the molecular weight of the polymer residue after heavy etching is the same as the molecular weight of the polymer before attack, within the accuracy of measurement.


2020 ◽  
Vol 13 (2) ◽  
pp. 176-186
Author(s):  
Armindo A. Campos Neto ◽  
Michael Jackson Oliveira Andrade ◽  
Ana Raquel Oliveira ◽  
Carine M. R. Costa ◽  
Natanael Antonio Santos

2020 ◽  
Author(s):  
Wei-Tse Lee ◽  
Felix D. Bobbink ◽  
Antoine P. van Muyden ◽  
Kun-Han Lin ◽  
Clémence Corminboeuf ◽  
...  

RSC Advances ◽  
2020 ◽  
Vol 10 (73) ◽  
pp. 44679-44687
Author(s):  
Lingyu Wang ◽  
Peng Chen ◽  
Xiuting Dong ◽  
Wen Zhang ◽  
Song Zhao ◽  
...  

Porous millimeter-sized MOF-808@PVDF composite beads with ultrahigh iodine adsorption capacity for capture of radioiodine from gas streams.


CORROSION ◽  
1960 ◽  
Vol 16 (10) ◽  
pp. 503t-506t ◽  
Author(s):  
KENNETH L. MOORE

Abstract Various corrosion problems are described which have occurred in a large diethanolamine (DEA) system that removes hydrogen sulfide from refinery gas streams and a liquid propane-butane stream. These include reboiler corrosion, rich DEA corrosion, stress corrosion cracking, and corrosion-erosion. The effect of the problems on system operation is discussed, as well as the means of minimizing the problems. Electrical resistance measuring device data indicate the importance of keeping the solution loading below 0.34 mol of acid gas (H2S + CO2) per mol of DEA to minimize the corrosion in the rich DEA. Data from this source also show the relationship between general reboiler corrosion and solution contamination. 8.4.3


Sign in / Sign up

Export Citation Format

Share Document